Solid screw insertion for tension band plates: a surgical technique tip

نویسندگان

  • Muayad Kadhim
  • Ahmed I. Hammouda
  • John E. Herzenberg
چکیده

PURPOSE Growth modulation with tension band plates (TBPs) and cannulated screws is the current mainstay of treatment for pediatric lower extremity angular deformities. Solid screws have been used as an alternative to cannulated screws to decrease the risk of screw failure, particularly in obese children. The downside of solid screws is the decrease in precision of placement. This study describes a surgical technique to insert solid TBP screws accurately. METHODS TBP insertion starts with the same conventional steps by inserting the guidewires into the epiphysis and metaphysis, straddling the physis. After fluoroscopic confirmation of the position of the guidewires, the cannulated drill bit is used to broach the cortex to a depth of 5 mm in the bone. A standard 4.5-mm cannulated screw from the TBP set is used to tap the screw tract over the guidewires for approximately three-quarters of the planned screw length. After removing the guidewires, the solid screws are then inserted in each hole to follow the tapped tracts. RESULTS This technique was used in five patients including four with Blount disease and one with bilateral genu varum. CONCLUSION It is recommended to use solid screws with TBPs in patients with a high body mass index to avoid screw fracture. Our technique describes using a cannulated screw as a tap to create a tract to ease accurate insertion of the solid screws, and prevent the solid screw from deviating outside the desired path.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biceps Tenodesis with Interference Screw Fixation: A Biomechanical Comparison of Screw Size and Technique

Introduction Numerous surgical procedures have been developed to address pathology associated with the long head of the biceps tendon. Tenodesis might be preferred over tenotomy for several reasons, including improved cosmetic appearance, maintenance of elbow flexion and supination strength, and maintenance of the biceps muscle length-tension relationship. To our knowledge, there have been no s...

متن کامل

Fully customized placement of orthodontic miniplates: a novel clinical technique

INTRODUCTION The initial stability and survival rate of orthodontic mini-implants are highly dependent on the amount of cortical bone at their insertion site. In areas with limited bone availability, mini-plates are preferred to provide effective skeletal anchorage. The purpose of this paper was to present a new clinical technique for the insertion of mini-plates. METHODS In order to apply th...

متن کامل

Effectiveness of the surgical torque limiter: a model comparing drill- and hand-based screw insertion into locking plates

BACKGROUND The objective of this study is to analyse the effectiveness of the surgical torque limiter during operative use. The study also investigates the potential differences in torque between hand and drill-based screw insertion into locking plates using a standardised torque limiter. METHODS Torque for both hand and power screw insertion was measured through a load cell, registering 6.66...

متن کامل

Cannulated Screw and Cable are Superior to Modified Tension Band in the Treatment of Transverse Patella Fractures

BACKGROUND Although the modified tension band technique (eg, tension band supplemented by longitudinal Kirschner wires) has long been the mainstay for fixation of transverse fractures of the patella, it has shortcomings, such as bad reduction, loosening of implants, and skin irritation. QUESTIONS/PURPOSES We conducted a retrospective comparison of the modified tension band technique and the t...

متن کامل

Improved accuracy of computer-assisted cervical pedicle screw insertion.

OBJECT The authors introduce a unique computer-assisted cervical pedicle screw (CPS) insertion technique used in conjunction with specially modified original pedicle screw insertion instruments. The accuracy of screw placement as well as surgery-related outcome and complication rates were compared between two groups of patients: those in whom a computer-assisted and those in whom a conventional...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 10  شماره 

صفحات  -

تاریخ انتشار 2016