Validity and interobserver reliability of visual observation to assess partial weight-bearing.

نویسندگان

  • Henri L Hurkmans
  • Johannes B Bussmann
  • Eric Benda
چکیده

OBJECTIVE To determine the validity and interobserver reliability of visual observation to assess partial weight-bearing. DESIGN Validation and interobserver reliability study. SETTING University medical center. PARTICIPANTS Patients (N=10) with a total hip arthroplasty operated 1 to 12 months prior to the study referred by 10 physical therapists (5 experienced and 5 inexperienced in training patients in partial weight-bearing). INTERVENTIONS Not applicable. MAIN OUTCOME MEASURES The amount of weight-bearing assessed by visual estimation (visual analog scale score) in percentage body weight (BW). Actual weight-bearing (percentage BW) as measured with the Pedar Mobile system. The mean difference (systematic error) between visual estimation and the Pedar system and the SD of the differences (random error) were determined by the limits of agreement (LOA) method with multiple observations per subject. The intraclass correlation coefficient (ICC) was calculated as a measure for the interobserver reliability. RESULTS The mean difference +/- SD between visual observation and the reference method was -9.5+/-20.1 percentage BW (95% confidence interval, -24.0 to 5.0 percentage BW) with LOA ranging from -49.8 to 30.8 percentage BW. The ICC was .57. The therapists' experience in partial weight-bearing training had no effect on the mean difference (P=.349) between the 2 methods. CONCLUSIONS Visual observation is not a valid and reliable method to assess partial weight-bearing.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Reliability and validity of the Sit-To-Stand Test to assess Global Foot Mobility

The Sit-to-Stand test (STST) involves comparing the change in a person’s non-weight-bearing and weightbearing foot posture to quickly classify a person’s overall foot mobility. Despite the simplicity of the test, its reliability and validity has not been established. The purpose of this study is to determine the intra-rater and inter-rater reliability of the STST as well as its validity. Ninety...

متن کامل

Osteoarthritis Classification Scales: Interobserver Reliability and Arthroscopic Correlation.

BACKGROUND Osteoarthritis of the knee is commonly diagnosed and monitored with radiography. However, the reliability of radiographic classification systems for osteoarthritis and the correlation of these classifications with the actual degree of confirmed degeneration of the articular cartilage of the tibiofemoral joint have not been adequately studied. METHODS As the Multicenter ACL (anterio...

متن کامل

Arch height change during sit-to-stand: an alternative for the navicular drop test

BACKGROUND A study was conducted to determine the reliability and validity of a new foot mobility assessment method that utilizes digital images to measure the change in dorsal arch height measured at 50% of the length of the foot during the Sit-to-Stand test. METHODS Two hundred - seventy five healthy participants participated in the study. The medial aspect of each foot was photographed wit...

متن کامل

Does Computed Tomography Change our Observation and Management of Fracture Non-Unions?

  Background: The purpose of this study was to determine whether Multi-Detector Computed Tomography (MDCT) in addition to plain radiographs influences radiologists’ and orthopedic surgeons’ diagnosis and treatment plans for delayed unions and non-unions.   Methods: A retrospective database of 32 non-unions was reviewed by 20 observers. On a scale of 1 to 5, observers rated on X-Ray and a...

متن کامل

The interobserver and intraobserver reliability of the Fernandez classification of distal radius fracture

 Abstract Background: With increasing knowledge concerning fractures of the distal radius, different classifications have been proposed. Reliability of most of these classifications has been assessed. The Fernandez classification has never been assessed for intraobserver and interobserver reliability, although this classification is commonly used. Methods: Five observers including one attending...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archives of physical medicine and rehabilitation

دوره 90 2  شماره 

صفحات  -

تاریخ انتشار 2009