Reproducible evaluation of spinal cord DTI using an optimized inner volume sequence in combination with probabilistic ROI analysis.
نویسندگان
چکیده
The purpose of this work was to reliably acquire and evaluate diffusion tensor data of the cervical spine. Thereto, we describe an optimized, time-efficient inner-volume echo planar imaging sequence. Multislice capability is achieved by restoring the magnetization in neighbouring slices early during the twice refocused diffusion preparation. The acquired diffusion images showed compelling image quality. To reduce the arbitrariness of conventional region of interest (ROI) analysis, a tissue classification algorithm was applied. The classification was independent of the ROI shape and hence, a reliable and stable evaluation of the diffusion tensor could be achieved. The mean fractional anisotropy (FA) of five healthy subjects decreased from C1 (FA = 0.81 +/- 0.03) to C7 (FA = 0.60 +/- 0.03), while the mean apparent diffusion coefficient (ADC) increased from C1 (ADC= 0.78 +/- 0.08 microm2/ms) to C7 (ADC = 1.08 +/- 0.08 microm2/ms). In subsequent measurements of the individual healthy subjects, the standard deviation of the FA was 0.024 +/- 0.011 and the standard deviation of the ADC was 0.045 +/- 0.017 microm2/ms. The FA values of a patient with acute ischemic spinal trauma were significantly lower and changed more drastically than ADC values. Here, absolute FA ranged from 0.23 to 0.42, showing that DTI of the spine may serve as surrogate marker for tissue integrity and therapy monitoring.
منابع مشابه
Diffusion tensor imaging of the normal pediatric spinal cord using an inner field of view echo-planar imaging sequence.
BACKGROUND AND PURPOSE DTI in the brain has been well established, but its application in the spinal cord, especially in pediatrics, poses several challenges. The small cord size has inherent low SNR of the diffusion signal intensity, respiratory and cardiac movements induce artifacts, and EPI sequences used for obtaining diffusion indices cause eddy-current distortions. The purpose of this stu...
متن کاملHuman cervical spinal cord funiculi: investigation with magnetic resonance diffusion tensor imaging.
PURPOSE To use spinal cord diffusion tensor imaging (DTI) for investigating human cervical funiculi, acquire axial diffusion magnetic resonance imaging (MRI) data with an in-plane resolution sufficient to delineate subquadrants within the spinal cord, obtain corresponding DTI metrics, and assess potential regional differences. MATERIALS AND METHODS Healthy volunteers were studied with a 3 T S...
متن کاملOptimizing Filter-Probe Diffusion Weighting in the Rat Spinal Cord for Human Translation
Diffusion tensor imaging (DTI) is a promising biomarker of spinal cord injury (SCI). In the acute aftermath, DTI in SCI animal models consistently demonstrates high sensitivity and prognostic performance, yet translation of DTI to acute human SCI has been limited. In addition to technical challenges, interpretation of the resulting metrics is ambiguous, with contributions in the acute setting f...
متن کاملPulse-triggered DTI sequence with reduced FOV and coronal acquisition at 3T for the assessment of the cervical spinal cord in patients with myelitis.
BACKGROUND AND PURPOSE DTI is a promising technique for imaging of the spinal cord, but the technique has susceptibility-induced artifacts. We evaluated a pulse-triggered DTI sequence with an rFOV technique and coronal acquisition for the assessment of the cervical spinal cord in patients with myelitis at 3T. MATERIALS AND METHODS A rFOV acquisition was established by a noncoplanar applicatio...
متن کاملTwice Refocused Inner Volume EPI DTI of the Spinal Cord: Initial Findings
Introduction Diffusion tensor imaging of the spinal cord is challenging due to the required high resolution, the susceptibility differences of the involved tissues and the pulsation of the surrounding CSF. Single shot Echo-Planar Imaging (EPI) is the method of choice, but has the drawback of being sensitive to local gradients when long readout trains are used. The readout train can be shorten b...