Investigation of the accuracy of tear lysozyme determination by the Quantiplate method.

نویسندگان

  • J R Copeland
  • D W Lamberts
  • F J Holly
چکیده

The accuracy of lysozyme concentration determination by the method of measuring lysis diameter in agarose gel slabs containing Micrococcus lysodeikticus bacteria uniformly suspended throughout the gel was determined for various methods of tear sample collection. The effects of storage of lysozyme solution samples at subzero temperatures for several days was also examined. It was found that a power rather than the suggested exponential dependence between the lysozyme concentration and lysis diameter provides the most accurate fit and thus should be used for interpolation. Storing samples frozen in glass capillaries lowered the lysozyme concentration in a predictable manner. When Weck-Cel sponges were used to collect the samples the lysozyme concentration was greatly diminished in a nonlinear manner because of internal adsorption. The relative loss (cause by adsorption) depended on the actual lysozyme concentration as well as on the sample volume/sponge weight ratio. Storing samples absorbed by such sponges in a frozen state further altered the results in an unpredictable way. The observation that smaller tear samples for a given sponge size yielded lower apparent values for lysozyme concentration casts doubt on findings that have reported lower lysozyme concentration in the tears of keratoconjunctivitis sicca patients, where either cellulose sponges or filter paper discs were used for tear collection.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

Development and validation of a fast, simple and specific stability indicating RP-HPLC method for determination of Dexpanthenol in eye gel formulation.

AIn this study a simple and reliable stability-indicating RP-HPLC method was developed and validated for analysis of Dexpanthenol in an artificial tear formulation. The chromatographic separation was performed on a HPLC C18 column (25.0 cm  4.6 mm, 5 m) using a mixture of 0.037 M monobasic potassium phosphate in water (adjusted with 0.1% (v/v) phosphoric acid to a pH of 3.2) and methanol (90:...

متن کامل

The study of Lysozyme adsorption onto 2-hydroxyethylmethacrylates and Silicon Hydrogel Contact Lenses

In order to increase the water content and the oxygen permeability of hydrogels used in themanufacture of contact lenses, the polar monomer Silicon Hydrogel Contact Lenses (SHCL), and 2-hydroxyethyl methacrylate (HEMA) were copolymerized with the hydrogels. Due to the presence ofpolar monomers in the conventional contact lenses, the major component of the human tear,lysozyme is extensively adso...

متن کامل

Quantitative tear lysozyme assay in units of activity per microlitre.

An accurate method of assaying the tear lysozyme concentration in units of activity/mul has been developed. Normal physiological levels which vary with age have been determined. It has been demonstrated that measurement of the volume of tear fluid collected and assay with a calibrated standard are essential for the accurate determination of the precise concentration of lysozyme in the tear flui...

متن کامل

Accuracy of MRI in Comparison with Arthroscopic Findings in the Diagnosis of Anterior Cruciate Ligament and Meniscus Tears

Background: Magnetic resonance imaging (MRI) is of great aid in the diagnosis of knee lesions. Nevertheless, arthroscopy has remained the reference standard for the diagnosis of internal derangements of the knee, against which alternative diagnostic modalities should be compared. This study was designed to assess the value of MRI and clinical examination in the diagnosis of Anterior Cruciate Li...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 1982