Calibration of Ac-dc Voltage Transfer Standards at Inmetro
نویسندگان
چکیده
The aim of this work is to present the AC-DC transfer calibration system of Voltage and Current Laboratory (Latce) of brazilian's Instituto Nacional de Metrologia, Normalização e Qualidade Industrial (Inmetro). Latce is responsible for the realizations of both the volt and the ampère in accordance to SI, and for it's dissemination through the network of accredited laboratories in Brazil, so as to assure traceabiblity of the national standards.
منابع مشابه
Improvements in the Nist Calibration Service for Thermal Transfer Standards
We report on multiple improvements made in the calibration services offered for thermal converters and thermal transfer standards in the ac-dc Difference Standards and Measurement Techniques Project at NIST during the past year. The major improvement in this calibration is the increased efficiency made possible by the consolidation of three disparate calibration services – low voltage thermal t...
متن کاملDC Voltage Linearity Measurements and DVM Calibration with Conventional and Programmable Josephson Voltage Standards
Traditional calibration of dc voltage high accuracy digital voltmeters (DVMs) using conventional and Programmable Josephson Voltage Standards at INMETRO show improvements between 73.7 % and 98.3 % when compared with a regular calibration technique. Some calibration results as well as DVM linearity and gain drift analysis (up to 10 V range) are presented and discussed in this paper.
متن کاملThe Calibration of dc Voltage Standards at NIST
This document describes the procedures used at NIST to calibrate dc voltage standards in terms of the NIST volt. Three calibration services are offered by the Electricity Division: Regular Calibration Service (RCS) of client standard cells at NIST; the Volt Transfer Program (VTP) a process to determine the difference between the NIST volt and the volt as maintained by a group of standard cells ...
متن کاملApplication of a Calorimetric Thermal Converter as a Standard of Ac-dc Voltage and Current Transfer Difference
At the National Research Council of Canada (NRC) the primary standard of AC-DC transfer difference at frequencies from 10 kHz to 100 MHz is a Calorimetric Thermal Voltage Converter (CTVC). Because of a simple design, not unlike a coaxial calorimeter for RF power measurements, its frequency characteristic can be estimated theoretically from a number of mechanical and electrical parameters. An in...
متن کاملAC-DC Transfer Standard Measurements Using An AC Josephson Voltage Standard
NIST is implementing the Josephson arbitrary waveform synthesizer as an ac Josephson Voltage Standard (ACJVS). Over the past few years we have demonstrated precise measurements of synthesized sine waves at rms voltage amplitudes up to 170 mV. The system can generate a variety of precision voltage outputs including dc voltages and ac sinewaves, so it can be used as a quantum-based voltage source...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011