Expanded polytetrafluoroethylene membranes to wrap surfaces of circulatory support devices in patients undergoing bridge to heart transplantation.

نویسندگان

  • P Leprince
  • M Rahmati
  • N Bonnet
  • V Bors
  • A Rama
  • P Léger
  • I Gandjbakhch
  • A Pavie
چکیده

OBJECTIVE Because of a lack of donor hearts, an increasing number of patients with heart failure must now undergo bridge to cardiac transplantation with a mechanical circulatory support device. Moreover, support periods have become longer. As a result, pericardial adhesions may develop while the support device is implanted, increasing the risk of injury at resternotomy and bleeding after transplantation. Use of expanded polytetrafluoroethylene (ePTFE) pericardial substitutes (membranes) may prevent such adhesions. PATIENTS AND METHODS From January 1997 to December 1999, ePTFE membranes were used in 23 patients to wrap portions of an implanted left ventricular assist device (LVAD) or total artificial heart (TAH). Any complications during mechanical support or at cardiac transplantation were recorded. Six ePTFE membranes removed at transplantation were studied histologically. RESULTS AND CONCLUSIONS At resternotomy for transplantation, the plane of dissection between tissues, ePTFE membranes, and surfaces of the mechanical support device were easily discerned. No adhesions were observed between tissues and membranes. There were no injuries during resternotomy and no patient had to undergo reoperation because of bleeding. One patient given a TAH had an infection during circulatory support that was controlled by antibiotic therapy. In another patient, clots developed between the device and an ePTFE membrane; these were removed successfully. Histologic studies of removed ePTFE membranes showed no infiltration of the membranes interstices by collagen or cellular components. Use of ePTFE membranes in patients undergoing bridge to transplantation with either an LVAD or a TAH limited adhesions between tissues and device surfaces without increasing the risk of infection.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

History of Mechanical Circulatory Support Devices

History of Mechanical Circulatory Support Devices Advanced heart failure (HF) is a major cause of morbidity and mortality in the United States, and heart transplantation remains as the gold standard therapy. Because of scarcity of donor organs, the application of mechanical circulatory support devices has become a crucial approach in HF therapy as a bridge to transplantation. Therefore, mechani...

متن کامل

Mechanical circulatory support for infants and small children.

The number of children in need of mechanical circulatory support has increased substantially over the last two decades, due to the technological progress made in surgery and intensive care, leading to improved survival of patients with congenital heart disease. In addition, primary myocardial dysfunction related to myocarditis or dilated cardiomyopathy may cause end-stage cardiac failure in chi...

متن کامل

Destination therapy--time for a paradigm change in heart failure therapy.

Heart transplantation is only available for a limited number of patients with end-stage heart failure. Since the arrival of newer ventricular assist devices, mechanical circulatory support constitutes an alternative therapy for patients with advanced heart failure. The first-generation of pulsatile-flow devices were used only for bridging the sickest patients to transplantation. Frequent advers...

متن کامل

Mechanical Circulatory Support of the Critically Ill Child Awaiting Heart Transplantation

The majority of children awaiting heart transplantation require inotropic support, mechanical ventilation, and/or extracorporeal membrane oxygenation (ECMO) support. Unfortunately, due to the limited pool of organs, many of these children do not survive to transplant. Mechanical circulatory support of the failing heart in pediatrics is a new and rapidly developing field world-wide. It is utiliz...

متن کامل

Mechanical circulatory support devices as destination therapy-current evidence.

Advanced heart failure is an increasing problem worldwide. Nowadays, mechanical circulatory support devices (MSCD) are an established therapeutic option for terminal heart failure after exhaustion of medical and conventional surgical treatment, and are becoming a realistic alternative to heart transplantation (HTX). There are a number of different treatment options for these patients, such as b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 19 3  شماره 

صفحات  -

تاریخ انتشار 2001