A two-dimensional Doppler echocardiographic method for calculation of pulmonary and systemic blood flow in a canine model with a variable-sized left-to-right extracardiac shunt.

نویسندگان

  • E J Meijboom
  • L M Valdes-Cruz
  • S Horowitz
  • D J Sahn
  • D F Larson
  • K A Young
  • C Oliveira Lima
  • S J Goldberg
  • H D Allen
چکیده

The purpose of this study was to validate a two-dimensional range-gated Doppler echocardiographic method for measurement of pulmonary and systemic blood flow in a canine model with a surgically created extracardiac systemic-to-pulmonary shunt, the size of which could be varied. In five anesthetized open-chest dogs, a previously calibrated electromagnetic (EM) flowmeter was placed around the ascending aorta, and the femoral artery was dissected, cannulated, and connected to a previously calibrated roller pump. The return tubing from the roller pump was inserted into the main pulmonary artery to create a variable-sized systemic-to-pulmonary artery shunt. In this preparation with intact ventricular and atrial septa, pulmonary blood flow volume was measured as flow from the ascending aorta with the EM flowmeter probe; left-to-right shunt volume was measured from the calibrated roller pump flow, and systemic flow was measured by subtraction of roller pump flow from the EM flowmeter reading of the ascending aorta. In two additional dogs, a 16 mm diameter, 12 cm long Teflon graft was placed between the descending aorta and the main pulmonary artery to mimic more closely a patent ductus arteriosus. Flow through the shunt was measured with an EM flowmeter probe placed around the graft. Systemic and pulmonary flows were then calculated by a Doppler echocardiographic method from RR interval-matched beats and compared with simultaneously recorded EM flowmeter measurements from the ascending aorta, and left-to-right shunt flows to permit comparison of pulmonary and systemic flows and their ratios (QP:QS) by both methods. Doppler systemic flow was measured as systemic venous return at the right ventricular outflow tract. The size of the outflow tract and mean flow as a function of time were obtained by echocardiographic imaging and interrogation of the outflow tract from a short-axis view. Pulmonary blood flow could not be measured at the pulmonary artery because of high multidirectional velocities and spectral broadening of the flow curves similar to those obtained in children with patent ductus arteriosus. Therefore, pulmonary blood flow was measured as pulmonary venous return through the mitral valve. The mitral orifice was measured from a short-axis view, and Doppler flow curves were recorded from the apical four-chamber view. For 26 left-to-right shunts, excellent correlations were obtained between Doppler echocardiographic andEM flowmeter measurements of pulmonary flows (range 1.2 to 7.7 1/min; r = .99, SEE = + 0.16 1/min), systemic flows (range 0.6 to 5.7 1/min; r = .99, SEE = ± 0.13), and QP:QS ratios (range 0.9:1 to 4.2:1; r = .96, SEE = ± 0.21:1). Our study validates the accuracy of this Doppler echocardiographic method to measure pulmonary and systemic flows and their ratios in the presence of extracardiac aortic-to-pulmonary artery shunts. Circulation 68, No. 2, 437-445, 1983. From the Department of Pediatrics, University of Arizona, Health OUR PREVIOUS STUDIES and those of other inSciences Center, Tucson, and the Department of Pediatrics, University vestigators have demonstrated that two-dimensional of Groningen, Groningen, The Netherlands. Supported in part by a grant from the Jan Kornelis de Cock FoundaDoppler echocardiographic methods are accurate for tion, The Netherlands. Address for correspondence: Lilliam Valdes-Cruz, M.D., Departnoninvasive calculation of cardiac flows in the intact ment of Pediatrics (Pediatric Cardiology), University of California San circulation in man. 1-10 Our own work has also shown Diego University Hospital, CTF B102, 225 West Dickinson St., San that Doppler echocardiography accurately measures Diego, CA 92103. Received Feb. 4, 1983; revision accepted April 25, 1983. pulmonary and systemic flows and their ratios, even in Vol. 68, No. 2, August 1983 437 by gest on N ovem er 8, 2017 http://ciajournals.org/ D ow nladed from

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A pulsed Doppler echocardiographic method for calculating pulmonary and systemic blood flow in atrial level shunts: validation studies in animals and initial human experience.

The purpose of this study was to assess the accuracy of a quantitative two-dimensional range-gated Doppler echocardiographic method for estimating systemic and pulmonary flows in an open-chest canine preparation with a variable-sized atrial level shunt mimicking an atrial septal defect. In addition, we also report our initial experience with 10 children who had isolated atrial septal defects an...

متن کامل

Noninvasive pulsed Doppler echocardiographic detection of the direction of shunt flow in patients with atrial septal defect: usefulness of the right parasternal approach.

Noninvasive pulsed Doppler echocardiography combined with two-dimensional echocardiography by the right parasternal approach was performed to detect the shunt flow through the defect in 31 patients with suspected secundum atrial septal defect (ASD). A defect of the interatrial septum was seen on the two-dimensional echocardiograms of 30 of 31 patients. In all the 30 patients, Doppler signals of...

متن کامل

Evaluation of Advanced Echocardiographic Parameters of Right Ventricular in Patients with Pulmonary Hypertension

Background and Objective: Pulmonary hypertension is an increase in blood pressure of the pulmonary artery which leads to right ventricular dysfunction. Therefore, the present study aimed to compare echocardiographic parameters in the study of right ventricular failure in patients with pulmonary hypertension. Materials and Methods: In the present descriptive cross-sectional study, data were col...

متن کامل

Study of Cardiac Parameters by Pulsed Wave Doppler Echocardiography in Normal Healthy Markhoz Goat

Objective- The aim of this study was to test the repeatability, the variability, and to establish the reference values of PW measurements in healthy Markhoz goats.Design- Retrospective study.Animals- 20 female Markhoz goats.Procedure- Using a standardized PW Doppler echocardiographic protocol, 20healthy adult unsedated female Markhoz goats were investigated three times at one-...

متن کامل

The prevalence of right to left shunt in chronic obstructive pulmonary disease patients with increased pulmonary hypertension

Background: One of the important etiologies for cryptogenic stroke is paradoxical embolization secondary to Patent Foramen Ovale (PFO). Foramen ovale can secondarily reopen due to Pulmonary Arterial Hypertension (PAH) which is common among the older age. PAH is known as a frequent and life threatening complication of COPD. The aim of this study was to determine the prevalence of PFO between COP...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation

دوره 68 2  شماره 

صفحات  -

تاریخ انتشار 1983