External quality assessment of multi-analyte chromatographic methods in oral fluid.

نویسندگان

  • Kristof Pil
  • Francis M Esposito
  • Alain Verstraete
چکیده

BACKGROUND A proficiency testing scheme was set up for the DRUID (Driving under the influence of Drugs, Alcohol and Medicines) research project, funded by the European Commission, in which oral fluid is analysed by eleven laboratories. A common collection and analysis methodology is used: Statsure Saliva Sampler is used for collection and LC-MS/MS or GC-MS confirmation analysis of 22 substances is performed on all samples. Despite internal validation and quality control samples, external quality assessment is still necessary to further increase comparability of results. Four rounds of proficiency testing (PT) were organized between March 2008 and September 2009. METHODS Qualitative results were evaluated using sensitivity and specificity. Quantitative results were evaluated using z-scores and the standard deviation of Horwitz. RESULTS Specificity was above 99% in each round, sensitivity per analyte varied between 81.7 and 100%, and 20 out of 22 analytes had a sensitivity above 90%. The percentage of satisfactory z-scores increased from 79.4% to 89.2%. This trend was seen for all drug classes, except zopiclone. Results were discussed with participating laboratories and problems were addressed. CONCLUSIONS Because of these corrective actions, DRUID laboratories have a lower variation in results than previously published PT schemes in oral fluid.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Mathematical modeling of a fixed bed chromatographic reactor for Fischer Tropsch synthesis

In this research, Fischer Tropsch synthesis (FTS) has been modeled in the fixed bed chromatographic reactor for the first time by applying a rather complex dispersed plug flow model for fluid phase and linear driving force (LDF) model for adsorbent. Model equations are dynamic, multi-component, non-linear and heterogeneous including reaction and adsorption simultaneously Complex kinetics fo...

متن کامل

A fast and simple method for the measurement of total antioxidant potential and a fingerprint of antioxidants.

The goal of this paper is to demonstrate a new approach to the chromatographic total antioxidant potential (TAP) assay and chromatographic fingerprints of honeys. The analyte is analyzed using reversed-phase high-performance liquid chromatography with electrochemical (amperometric) detection. The TAP measure was the total surface area of all recorded chromatographic peaks (on the amperometric d...

متن کامل

Simultaneous monitoring of selective serotonin reuptake inhibitors in human urine, plasma and oral fluid by reverse-phase high performance liquid chromatography.

A simple and rapid reverse-phase high-performance liquid chromatography method is developed for the simultaneous determination of selective serotonin reuptake inhibitors (sertraline, citalopram, paroxetine and fluoxetine) in urine, plasma and oral fluid. Separation was performed on a Crestpack-18 column (4.6 × 250 mm × 5 µ) within 17.5 min. The mobile phase was composed of water (50 mL) [with g...

متن کامل

A diagnostic test for cocaine and benzoylecgonine in urine and oral fluid using portable mass spectrometry

Surface mass spectrometry methods can be difficult to use effectively with low cost, portable mass spectrometers. This is because commercially available portable (single quadrupole) mass spectrometers lack the mass resolution to confidently differentiate between analyte and background signals. Additionally, current surface analysis methods provide no facility for chromatographic separation and ...

متن کامل

I-4: External Quality Assessment - A Necessity in The Andrology Laboratory

Andrology laboratories need to produce reliable results for appropriate diagnostic and health care decisions. Since semen analysis is highly complex and procedurally difficult to standardize, quality control (QC) is essential to detect and correct systematic errors and high variability of results. The large discrepancies between assessments of sperm concentration and morphology in different lab...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinica chimica acta; international journal of clinical chemistry

دوره 411 15-16  شماره 

صفحات  -

تاریخ انتشار 2010