Noninvasive optical evaluation of spontaneous low frequency oscillations in cerebral hemodynamics

نویسندگان

  • Ran Cheng
  • Yu Shang
  • Don Hayes
  • Sibu P. Saha
  • Guoqiang Yu
چکیده

Spontaneous low frequency oscillations (LFOs) around 0.1 Hz have been observed in mean arterial pressure (MAP) and cerebral blood flow velocity (CBFV). Previous studies have shown that cerebral autoregulation in major arteries can be assessed by quantification of the phase shift between LFOs of MAP and CBFV. However, many cerebral diseases are associated with abnormal microvasculature and tissue dysfunction in brain, and quantification of these abnormalities requires direct measurement of cerebral tissue hemodynamics. This pilot study used a novel hybrid near-infrared diffuse optical instrument to noninvasively and simultaneously detect LFOs of cerebral blood flow (CBF) and cerebral oxygenation (i.e., oxygenated/deoxygenated/total hemoglobin concentration: [HbO(2)]/[Hb]/THC) in human prefrontal cortex. Using the hybrid instrument and a finger plethysmograph, the dynamic changes of CBF, [HbO(2)], [Hb], THC and MAP were concurrently measured in 15 healthy subjects at rest, during 70° head-up-tilting (HUT) and during enforced breathing at 0.1 Hz. The LFOs were extracted from the measured variables using power spectral analysis, and the phase shifts and coherences of LFOs between MAP and each of the measured hemodynamic variables were calculated from the corresponding transfer functions. Levels of coherence (>0.4) were used to judge the success of LFO measurements. We found that CBF, [HbO(2)] and THC were reliable hemodynamic parameters in detecting LFOs and HUT was the most robust and stable protocol for quantifying phase shifts of hemodynamic LFOs. Comparing with other relevant studies, similar success rates for detecting cerebral LFOs have been achieved in our study. The phase shifts of LFOs in CBF were also close to those in CBFV reported by other groups, although the results in cerebral oxygenation measurements during enforced breathing varied across studies. Future study will investigate cerebral LFOs in patients with cerebral impairment and evaluate their cerebral autoregulation capabilities and neurocognitive functions via the quantification of LFO phase shifts.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Very-low-frequency oscillations of cerebral hemodynamics and blood pressure are affected by aging and cognitive load

Spontaneous slow oscillations occur in cerebral hemodynamics and blood pressure (BP), and may reflect neurogenic, metabolic or myogenic control of the cerebral vasculature. Aging is accompanied by a degeneration of the vascular system, which may have consequences for regional cerebral blood flow and cognitive performance. This degeneration may be reflected in a reduction of spontaneous slow osc...

متن کامل

Phase-amplitude investigation of spontaneous low-frequency oscillations of cerebral hemodynamics with near-infrared spectroscopy: A sleep study in human subjects

We have investigated the amplitude and phase of spontaneous low-frequency oscillations (LFOs) of the cerebral deoxy- and oxy-hemoglobin concentrations ([Hb] and [HbO]) in a human sleep study using near-infrared spectroscopy (NIRS). Amplitude and phase analysis was based on the analytic signal method, and phasor algebra was used to decompose measured [Hb] and [HbO] oscillations into cerebral blo...

متن کامل

Spontaneous Low-Frequency Cerebral Hemodynamics Oscillations in Restless Legs Syndrome with Periodic Limb Movements During Sleep: A Near-Infrared Spectroscopy Study

BACKGROUND AND PURPOSE Periodic limb movements (PLM) during sleep (PLMS) are associated with cortical and cardiovascular activation. Changes in cerebral hemodynamics caused by cortical activity can be measured using near-infrared spectroscopy (NIRS). We investigated oscillatory components of cerebral hemodynamics during PLM and different sleep stages in restless legs syndrome (RLS) patients wit...

متن کامل

Blood flow and oxygenation changes due to low-frequency repetitive transcranial magnetic stimulation of the cerebral cortex.

Transcranial magnetic stimulation (TMS) modulates processing in the human brain and is therefore of interest as a treatment modality for neurologic conditions. During TMS administration, an electric current passing through a coil on the scalp creates a rapidly varying magnetic field that induces currents in the cerebral cortex. The effects of low-frequency (1 Hz), repetitive TMS (rTMS) on motor...

متن کامل

Phase Difference between Low-frequency Oscillations of Cerebral Deoxy- and Oxy-hemoglobin Concentrations during a Mental Task.

Hemodynamic low-frequency (~0.1 Hz) spontaneous oscillations as detected in the brain by near-infrared spectroscopy have potential applications in the study of brain activation, cerebral autoregulation, and functional connectivity. In this work, we have investigated the phase lag between oscillations of cerebral deoxy- and oxy-hemoglobin concentrations in the frequency range 0.05-0.10 Hz in a h...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NeuroImage

دوره 62 3  شماره 

صفحات  -

تاریخ انتشار 2012