Non-Contact Methods for Measuring Front Cavity Depths of Laboratory Standard Microphones Using a Depth-Measuring Microscope
نویسندگان
چکیده
To achieve an acceptable degree of accuracy at high frequencies in some standardized methods for primary calibration of laboratory standard (LS) microphones, the front cavity depth lfc of each microphone must be known. This dimension must be measured using non-contact methods to prevent damage to the microphone diaphragm. The basic capabilities of an optical depth-measuring microscope were demonstrated by the agreement of its measurements within 0.7 μm of the known values of reference gage blocks. Using this microscope, two basic methods were applied to measure lfc . One (D) uses direct measurements at the microphone front surface annulus and conventional data reduction techniques. The other (GB) uses measurements at the surface of a gage block placed on the annulus, and plane-fitting data reduction techniques intended to reduce the effects of the slightly imperfect geometries of the microphones. The GB method was developed to provide a smoother surface of measurement than the relatively rough surface of the annulus, and to simulate the contact that occurs between the annulus and the smooth, plane surface of an acoustic coupler during microphone calibration. Using these methods, full data sets were obtained at 33 measurement positions (D), or 25 positions (GB). In addition, D and GB subsampling methods were applied by using subsamples of either the D or the GB full data sets. All these methods were applied to six LS microphones, three each of two different types. The GB subsampling methods are preferred for several reasons. The measurement results for lfc obtained by these methods agree well with those obtained by the GB method using the full data set. The expanded uncertainties of results from the GB subsampling methods are not very different from the expanded uncertainty of results from the GB method using the full data set, and are smaller than the expanded uncertainties of results from the D subsampling methods. Measurements of lfc using the GB subsampling method with only nine measurement positions exhibit expanded uncertainties (with coverage factor k = 2) within 4 μm, and can improve the uncertainty of microphone calibrations by an order of magnitude over the result from use of generic standardized microphone type nominal lfc values and tolerance limits.
منابع مشابه
Measuring infiltration rate and hydraulic conductivity in a dry well in a thin overburden
IInfiltration rate and hydraulic conductivity are immensely important parameters for evaluating the hydrology of subsurface environments. Specifically, in disposal wells schemes and in artificial recharge plans both properties must be correctly assessed to better analyze the performance of these installations. In a new research, tanker water and rainfall runoff were injected into a 22.5 m deep ...
متن کاملMeasuring midline dose without build-up cap for patients with brain tumor undergoing 15MV external radiotherapy by using EBT3 Gafchromic film
Introduction: The Purpose of this study has been measuring midline dose for the patients undergoing brain radiotherapy without any need to build-up cap. Materials and Methods: The study was performed on 28 patients with brain tumor undergoing 15 MV radiotherapy by a Siemens LINAC. To estimate the midline dose, the entrance and exit doses were calculated b...
متن کاملComparison between a profilometer and a measuring microscope for measurement of enamel erosion.
The aim of this study was to measure the difference in the erosion depth of enamel measured by profilometry (PM) and a measuring microscope (MM). Sixty enamel specimens were divided into ten groups. Each specimen group was exposed to 50 ml of a carbonated drink with pH 2.38 or orange juice with pH 3.67 for 15, 30, 60, 120, and 180 minutes. Depths of eroded areas were measured with a profilomete...
متن کاملMeasuring and Simulating 2,4-D Residues in Silty Clay Soil Profile Under Two Water Regimes Using a LEACHP Model
The extensive use of pesticides in agriculture is compromising soil and water quality. One major concern is protecting water resources from contamination. The main objective of this research was measuring 2,4- D in a silty clay soil and simulating temporal transportation of this herbicide in soil using a LEACHP model, in a corn root zone field. 2,4- D was applied at 3.5 kg a.i./ha, followed by ...
متن کاملA Review of Laboratory Methods for Measuring Oxidative Stress
Introduction: Antioxidant defense system, including enzymatic and non-enzymatic antioxidants, protects cells from oxidative damage by neutralizing oxidant compounds. Increasing the production of oxidant species and decrease activity of antioxidant system causes oxidative stress. The role of oxidative stress in the pathogenesis of human diseases and strengthening of human antioxidant defense sys...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 113 شماره
صفحات -
تاریخ انتشار 2008