Two-phase refrigerant flow instability analysis and active control in transient electronics cooling systems
Two-loop refrigeration systems are being explored for two-phase cooling of ultra high power electronic components. For effective and efficient thermal management of electronic systems, active control methods are desired to suppress inherent flow instabilities especially in transient applications. This paper presents a framework for the transient analysis and active control of pressure-drop flow...
متن کاملExperimental Study on the Effect of Stabilization on Flow Boiling Heat Transfer in Microchannels
The effect of flow instabilities on flow boiling heat transfer in microchannels is investigated using water as the working fluid. The experimental test section has six parallel rectangular microchannels with each having a cross sectional area of 1054 × 197 microns. Flow restrictors are introduced at the inlet of each microchannel to stabilize the flow boiling process and avoid the backflow phen...
متن کاملExperimental Investigation and Theoretical Model for Subcooled Flow Boiling Pressure Drop in Microchannel Heat Sinks
This study examines the pressure drop characteristics of subcooled two-phase microchannel heat sinks. A new model is proposed, which depicts the subcooled flow as consisting of a homogeneous two-phase flow layer near the heated walls of the microchannel and a second subcooled bulk liquid layer. This model is intended for conditions where subcooled flow boiling persists along the entire microcha...
متن کاملEffects of Dissolved Air on Subcooled Flow Boiling of a Dielectric Coolant in a Microchannel Heat Sink
The effects of dissolved air in the dielectric liquid FC-77 on flow boiling in a microchan-nel heat sink containing ten parallel channels, each 500 m wide and 2.5 mm deep, were experimentally investigated. Experiments were conducted before and after degas-sing, at three flow rates in the range of 30– 50 ml/ min. The dissolved air resulted in a significant reduction in wall temperature at which...
متن کاملSubcooled two-phase flow boiling in a microchannel heat sink: comparison of conventional numerical models
Subcooled flow boiling in multi-microchannels can be used as an efficient thermal management approach in compact electrical devices. Highly subcooled flow boiling of HFE 7100 is studied in two microchannel heat sinks to choose a proper numerical model for simulating boiling flows in microchannels. Results of five different numerical models, including Volume of Fluid (VOF), Eulerian boiling, Eul...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2010