Clinical impact of combination of scatter, attenuation correction, and depth-dependent resolution recovery for (201)Tl studies.

نویسندگان

  • F Harel
  • R Génin
  • D Daou
  • R Lebtahi
  • N Delahaye
  • B O Helal
  • D Le Guludec
  • M Faraggi
چکیده

UNLABELLED A lack of specificity for myocardial perfusion imaging has been widely reported, mostly related to false-positive defects on the inferior wall. The application of depth-dependent resolution recovery (RR), attenuation correction (AC) using external source devices, and scatter correction has been proposed to resolve this pitfall. METHODS We studied the clinical benefit of depth-dependent RR, nonuniform AC using a scanning line source, and scatter correction (photon energy recovery [PER]) compared with filtered backprojection alone. Eighty-two patients were included: 40 healthy volunteers with a low likelihood of coronary artery disease (control group) and 42 patients with proven right or circumflex coronary artery disease but without involvement of the left anterior descending artery. Among these 82 patients, the images of 33 were also processed with PER. RESULTS RR did not alter the performance of filtered backprojection alone. AC + RR greatly improved specificity and the rate of normal (201)Tl SPECT findings in the control population (from 56% to 95% and from 53% to 100%, respectively) but significantly decreased sensitivity (from 92% to 54%). AC + RR generated a false anteroapical defect in 21% of patients and reverse redistribution of the apex in 23%. AC + RR significantly decreased the extent of the stress defect (from 4.09 to 3.21 segments, P < 0.003) and increased the perfusion score of the stress defect (from 0.78 +/- 0.72 to 1.47 +/- 1.11, P < 0.00061). Moreover, AC + RR generated overcorrection on the inferior wall, leading to false estimation of viability for 11 of 15 patients with an old inferior myocardial scar without evidence of residual viability. PER decreased overcorrection on the inferior wall, but without improving sensitivity. PER did not significantly reduce the number of anteroapical false-positives or the number of apical reverse distribution cases. CONCLUSION AC + RR improved the specificity and normalcy rate of (201)Tl SPECT myocardial perfusion imaging but generated overcorrection on the inferior wall, leading to low sensitivity and to false evaluation of myocardial viability in 73% of the patients with inferior infarction. AC + RR also generated anteroapical artifacts. The addition of scatter correction did not significantly reduce these drawbacks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Relative impact of scatter, collimator response, attenuation, and finite spatial resolution corrections in cardiac SPECT.

UNLABELLED We determined the relative effect of corrections for scatter, depth-dependent collimator response, attenuation, and finite spatial resolution on various image characteristics in cardiac SPECT. METHODS Monte Carlo simulations and real acquisition of a 99mTc cardiac phantom were performed under comparable conditions. Simulated and acquired data were reconstructed using several correc...

متن کامل

Optimisation of Simultaneous Tl-201/Tc-99m Dual Isotope Reconstruction with Monte-Carlo-Based Scatter Correction

Simultaneous Tl-201/Tc-99m dual isotope myocardial perfusion SPECT is seriously hampered by down-scatter from Tc-99m into the Tl-201 energy window. This paper presents and optimises the ordered-subsets-expectation-maximisation-(OS-EM-) based reconstruction algorithm, which corrects the down-scatter using an efficient Monte Carlo (MC) simulator. The algorithm starts by first reconstructing the T...

متن کامل

Evaluation of iterative reconstruction method and attenuation correction on brain dopamine transporter SPECT using anthropomorphic striatal phantom

Objective(s): The aim of this study was to determine the optimal reconstruction parameters for iterative reconstruction in different devices and collimators for dopamine transporter (DaT) single-photon emission computed tomography (SPECT). The results were compared between filtered back projection (FBP) and different attenuation correction (AC) methods.Methods: An anthropomorphic striatal phant...

متن کامل

Optimization of iterative reconstruction parameters with attenuation correction, scatter correction and resolution recovery in myocardial perfusion SPECT/CT.

OBJECTIVE The aim of this study was to characterize the optimal reconstruction parameters for ordered-subset expectation maximization (OSEM) with attenuation correction, scatter correction, and depth-dependent resolution recovery (OSEMACSCRR). We assessed the optimal parameters for OSEMACSCRR in an anthropomorphic torso phantom study, and evaluated the validity of the reconstruction parameters ...

متن کامل

Evaluation of 3D Monte Carlo-based scatter correction for 201Tl cardiac perfusion SPECT.

UNLABELLED (201)Tl-Chloride ((201)Tl) is a myocardial perfusion SPECT agent with excellent biochemical properties commonly used for assessing tissue viability. However, cardiac (201)Tl SPECT images are severely degraded by photons scattered in the thorax. Accurate correction for this scatter is complicated by the nonuniform density and varied sizes of thoraxes, by the additional attenuation and...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 42 10  شماره 

صفحات  -

تاریخ انتشار 2001