Clinical outcome of Brånemark System implants of various diameters: a retrospective study.

نویسندگان

  • Bertil Friberg
  • Annika Ekestubbe
  • Lars Sennerby
چکیده

PURPOSE The purpose of this study was to evaluate the outcome of the 3 different diameters of Brånemark System implants, with special focus on the 5.0-mm-diameter implant. MATERIALS AND METHODS Ninety-eight patients (99 jaws) with a mean age of 62 years were included in this retrospective report. The mean follow-up period was 2 years and 8 months. A total of 379 Brånemark System implants (3.75 mm diameter, n = 146; 4.0 mm diameter, n = 76; 5.0 mm diameter, n = 157) were placed in 29 edentulous and 70 partially edentulous jaws. RESULTS Eight of the 146 implants in the 3.75-mm-diameter group failed (5.5%). The corresponding figures for the 4.0- and 5.0-mm-diameter implants were 3 of 76 (3.9%) and 7 of 157 (4.5%), respectively. DISCUSSION All failures were recorded in maxillae, ie, 18 of the 298 placed, and the majority of these were found in bone quantity group B and quality group 2. Only 3 implants of 131 failed in bone judged as quality 4. The marginal bone loss was low for the 3 implant diameter groups. CONCLUSION The favorable outcome in bone of poor quality is ascribed partly to the use of an adapted preparation technique and extended healing periods for achievement of the best primary and secondary implant stability possible.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

"All-on-Four" immediate-function concept with Brånemark System implants for completely edentulous mandibles: a retrospective clinical study.

BACKGROUND Immediate-function Brånemark System implants (Nobel Biocare AB, Gothenburg, Sweden) have become an accepted alternative for fixed restorations in edentulous mandibles, based on documented high success rates. Continuous development is ongoing to find simple protocols for their use. PURPOSE The purpose of this study was to develop and document a simple, safe, and effective surgical a...

متن کامل

Analysis of the 619 Brånemark System TiUnite implants: a retrospective study.

The purpose of this retrospective study was to determine the outcome of Brånemark System TiUnite® implants (Nobel Biocare/Sweden), and to identify the risk factors associated with implant failure. A total of 151 patients (83 maxillae and 91 mandibles) received 619 implants from July 2003 until May 2010. The patients included 86 males and 65 females, with a median age of 51.6 years and an ag...

متن کامل

Early implant failures in patients treated with Brånemark System titanium dental implants: a retrospective study.

Implant failure has been associated with factors such as poor bone quality, insufficient bone volume, implant instability, unfavorable implant loading, and smoking habits. Infections and host responses may also be important factors in dental implant failure. The objectives of the present study were to identify various explanatory factors associated with titanium implant failure. Forty subjects ...

متن کامل

Risk Factors and Early Survival Rate of Biomet 3i Dental Implants. A Retrospective Study

Introdouction: Although highly desirable outcomes and longterm survival of dental implant treatments are well documented, implant failures still occur due to various reasons. Several risk factors may impair implant survival including implant dimensions (length, diameter, and implant design), procedures, local bone density at the implant site, and patient-related risk factors such as age, smokin...

متن کامل

Clinical evaluation of short, machined-surface implants followed for 12 to 92 months.

PURPOSE Bone resorption following tooth loss often limits the quantity of bone available for implant placement. The purpose of the present study was to evaluate the clinical outcome of 10-mm or shorter machined-surface implants when used exclusively in the treatment of various forms of edentulism. MATERIALS AND METHODS Two hundred sixty-nine screw-type Brånemark System implants (Nobel Biocare...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 17 5  شماره 

صفحات  -

تاریخ انتشار 2002