In Defence of RANSAC for Outlier Rejection in Deformable Registration
نویسندگان
چکیده
This paper concerns the robust estimation of non-rigid deformations from feature correspondences. We advance the surprising view that for many realistic physical deformations, the error of the mismatches (outliers) usually dwarfs the effects of the curvature of the manifold on which the correct matches (inliers) lie, to the extent that one can tightly enclose the manifold within the error bounds of a low-dimensional hyperplane for accurate outlier rejection. This justifies a simple RANSACdriven deformable registration technique that is at least as accurate as other methods based on the optimisation of fully deformable models. We support our ideas with comprehensive experiments on synthetic and real data typical of the deformations examined in the literature.
منابع مشابه
Outlier rejection in high-dimensional deformable models
Deformable model tracking is a powerful methodology that allows us to track the evolution of high-dimensional parameter vectors from uncalibrated monocular video sequences. The core of the approach consists of using low-level vision algorithms, such as edge trackers or optical flow, to collect a large number of 2D displacements, or motion measurements, at selected model points and mapping them ...
متن کاملFast Outlier Rejection by Using Parallax-Based Rigidity Constraint for Epipolar Geometry Estimation
A novel approach is presented in order to reject correspondence outliers between frames using the parallax-based rigidity constraint for epipolar geometry estimation. In this approach, the invariance of 3-D relative projective structure of a stationary scene over different views is exploited to eliminate outliers, mostly due to independently moving objects of a typical scene. The proposed appro...
متن کاملEvaluation of deformable image registration in HDR gynecological brachytherapy
Introduction: In brachytherapy, as in external radiotherapy, image-guidance plays an important role. For GYN treatments it is standard to acquire at least CT images and preferably MR images prior to each treatment and to calculate the dose of the day on each set of images. Then, the dose to the target and to the organs at risk (OAR) is calculated with worst case scenario from I...
متن کاملA Study on Robustness of Various Deformable Image Registration Algorithms on Image Reconstruction Using 4DCT Thoracic Images
Background: Medical image interpolation is recently introduced as a helpful tool to obtain further information via initial available images taken by tomography systems. To do this, deformable image registration algorithms are mainly utilized to perform image interpolation using tomography images.Materials and Methods: In this work, 4DCT thoracic images of five real patients provided by DI...
متن کاملFeature-Based Deformable Image Registration with RANSAC Based Search Correspondence
The paper presents an algorithm for deformable image registration based on point features extracted from input images using the Harris corner detector. The correspondence between the points extracted from the different images is established using RANdom SAmple Consensus (RANSAC) method with the affine and perspective global transformation used to model the deformations. The initial corresponden...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012