Multisite analytical evaluation of the Abbott ARCHITECT cyclosporine assay.

نویسندگان

  • Pierre Wallemacq
  • Gregory T Maine
  • Keith Berg
  • Thomas Rosiere
  • Pierre Marquet
  • Giuseppe Aimo
  • Giulio Mengozzi
  • Julianna Young
  • Kurt Wonigeit
  • Robert Kretschmer
  • Bendicht Wermuth
  • Rainer W Schmid
چکیده

The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Cyclosporine (CsA) immunoassay in 7 clinical laboratories in comparison to liquid chromatography/tandem mass spectrometry (LC/MS/MS), Abbott TDx, Cobas Integra 800, and the Dade Dimension Xpand immunoassay. The ARCHITECT assay uses a whole blood specimen, a pretreatment step with organic reagents to precipitate proteins and extract the drug, followed by a 2-step automated immunoassay with magnetic microparticles coated with anti-CsA antibody and an acridinium-CsA tracer. Imprecision testing at the 7 evaluation sites gave a range of total % coefficient of variations of 7.5%-12.2% at 87.5 ng/mL, 6.6%-14.3% at 411 ng/mL, and 5.2%-10.7% at 916 ng/mL. The lower limit of quantification ranged from 12 to 20 ng/mL. Purified CsA metabolites AM1, AM1c, AM4N, AM9, and AM19 were tested in whole blood by the ARCHITECT assay and showed minimal cross-reactivity at all 7 sites. In particular, AM1 and AM9 cross-reactivity in the ARCHITECT assay, ranged from -2.5% to 0.2% and -0.8% to 2.2%, respectively, and was significantly lower than for the TDx assay, in which the values were 3.2% and 16.1%, respectively. Comparable testing of metabolites in the Dade Dimension Xpand assay at 2 evaluation sites showed cross-reactivity to AM4N (6.4% and 6.8%) and AM9 (2.6% and 3.6%) and testing on the Roche Integra 800 showed cross-reactivity to AM1c (2.4%), AM9 (10.7%), and AM19 (2.8%). Cyclosporine International Proficiency Testing Scheme samples, consisting of both pooled specimens from patients receiving CsA therapy as well as whole-blood specimens supplemented with CsA, were tested by the ARCHITECT assay at 6 sites and showed an average bias of -24 to -58 ng/mL versus LC/MSMS CsA and -2 to -37 ng/mL versus AxSYM CsA. Studies were performed with the ARCHITECT CsA assay on patient specimens with the following results: ARCHITECT CsA assay versus LC/MSMS, average bias of 31 ng/mL; ARCHITECT versus the Dade Dimension assay (4 sites), average biases of -7 to -228 ng/mL; ARCHITECT versus AxSYM and TDx, average biases of -4 and -53 ng/mL, respectively. Spearman correlation coefficients were >or=0.89. The ARCHITECT CsA assay has significantly reduced CsA metabolite interference relative to other immunoassays and is a convenient and sensitive semiautomated method to measure CsA in whole blood.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Performance evaluation and cross-reactivity from insulin analogs with the ARCHITECT insulin assay.

BACKGROUND Insulin measurement is used for the diagnosis of hypoglycemia and for insulin pharmacokinetic evaluations. We assessed the analytical and clinical performance of the ARCHITECT insulin assay, a chemiluminescent immunoassay recently introduced for the ARCHITECT i2000 fully automated immunoassay analyzer (Abbott Laboratories). We also tested whether major insulin analogs cross-reacted w...

متن کامل

Evaluation of the Abbott ARCHITECT HCV Ag Assay

Eight hundred and three samples from a single HCV antibody negative diagnostic population were tested on the Abbott ARCHITECT HCV Ag assay. All samples initially reactive were retested in duplicate. Samples repeatedly reactive were tested for HCV RNA to determine the true status. Samples that were confirmed as positive were excluded from the specificity and negative delta calculations. A total ...

متن کامل

Comparison of Architect I 2000 for Determination of Cyclosporine with Axsym

BACKGROUND Cyclosporine has been shown effective drug in suppressing acute rejection in recipients of allograft organ transplants. METHODS The cyclosporine concentration of 96 blood samples was determined using CMIA (chemiluminesecent microparticle immnoassay) Architect i 2000 and FPIA (fluorescence polarization immunoassay) AxSYM Abbott diagnostic. All patients have transplantation of kidney...

متن کامل

Multi-center Performance Evaluations of Tacrolimus and Cyclosporine Electrochemiluminescence Immunoassays in the Asia-Pacific Region

BACKGROUND The immunosuppressant drugs (ISDs), tacrolimus and cyclosporine, are vital for solid organ transplant patients to prevent rejection. However, toxicity is a concern, and absorption is highly variable across patients; therefore, ISD levels need to be precisely monitored. In the Asia-Pacific (APAC) region, tacrolimus and cyclosporine concentrations are typically measured using immunoass...

متن کامل

Multi-site analytical evaluation of the Abbott ARCHITECT tacrolimus assay.

The objective of this study was to evaluate the analytical performance of the Abbott ARCHITECT Tacrolimus immunoassay. Proficiency panels and specimens from a population of organ transplant recipients were analyzed in 6 clinical laboratories in Europe and the United States, and the results were compared with other methods. The ARCHITECT assay requires a whole blood specimen pretreatment step wi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Therapeutic drug monitoring

دوره 32 2  شماره 

صفحات  -

تاریخ انتشار 2010