Methods for measuring plasma hemoglobin in micromolar concentration compared.
نویسندگان
چکیده
Of eight methods examined for measuring plasma hemoglobin in micromolar concentration, all exhibited acceptable linearity, reproducibility, and concurrence except when specimens were icteric or lipemic or contained methemoglobin or methemalbumin. Measurement of absorbance at 578 nm with an Allen correction permits precise assay of plasma oxyhemoglobin concentration as low as 0.01 g/L (1 mg/dL, 0.16 mumol/L), unaffected by hyperlipidemia or hyperbilirubinemia. Discrepancies between methods occurred in 11.6% of a consecutive series of 50 nonicteric patients' plasma specimens. Examination of absorption spectra is helpful when discrepancies are observed between methods. The presence of methemalbumin or methemoglobin in plasma is not recognized by methods that measure only oxyhemoglobin. Increased ceruloplasmin or beta-carotene does not significantly affect results.
منابع مشابه
Assessment of Photoplethysmography Method in Extraction of Hemoglobin Concentration
Background: The importance of continuous monitoring along with rapid and accurate notification of changes in blood components such as hemoglobin concentration, especially in acute situations, encourages researchers to use non-invasive methods for measuring.Objective: This study was aimed to investigate the correlation between hemoglobin concentration and photoplethysmogram (PPG) and the p...
متن کاملHigh maternal hemoglobin concentration in first trimester as risk factor for pregnancy induced hypertension
Background: High maternal hemoglobin (Hb) concentration was considered a risk factor for the developing of pregnancy hypertension. The purpose of this study was to determine whether high maternal Hb concentration in first trimesters associated with pregnancy induced hypertension in Iranian nulliparous women. Methods: This study was carried out in teaching hospital in Sari, Iran. Samples were ob...
متن کاملDesign and construction of a portable unite for measuring body-fluid components
Introduction: In the laboratory, the time required to measure body-fluids components is usually one to two working days. The laboratory methods require sample preparation and instrument cleaning after the sample reading. In emergency scenarios, the physician does not have much time to make a clinical decision. To solve these challenges, a portable system for measuring the body fluids components...
متن کاملVariability in hematology and plasma indices of common carp Cyprinus carpio, associated with age, sex and hormonal treatment
The purpose of this study was to determine changes in hematological and plasma indices of Common Carp Cyprinus carpio with regard to age, sex and hormonal treatment. Sixty fish were used to assess the age factor. Also, 20 fish including female and male were assigned to determine blood indices with regard to sex and hormonal treatment. The pituitary gland extract was used as hormone for males an...
متن کاملVariability in hematology and plasma indices of common carp Cyprinus carpio, associated with age, sex and hormonal treatment
The purpose of this study was to determine changes in hematological and plasma indices of Common Carp Cyprinus carpio with regard to age, sex and hormonal treatment. Sixty fish were used to assess the age factor. Also, 20 fish including female and male were assigned to determine blood indices with regard to sex and hormonal treatment. The pituitary gland extract was used as hormone for males an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 38 1 شماره
صفحات -
تاریخ انتشار 1992