Mechanics Based Tomography: A Preliminary Feasibility Study

نویسندگان

  • Yue Mei
  • Sicheng Wang
  • Xin Shen
  • Stephen Rabke
  • Sevan Goenezen
چکیده

We present a non-destructive approach to sense inclusion objects embedded in a solid medium remotely from force sensors applied to the medium and boundary displacements that could be measured via a digital image correlation system using a set of cameras. We provide a rationale and strategy to uniquely identify the heterogeneous sample composition based on stiffness (here, shear modulus) maps. The feasibility of this inversion scheme is tested with simulated experiments that could have clinical relevance in diagnostic imaging (e.g., tumor detection) or could be applied to engineering materials. No assumptions are made on the shape or stiffness quantity of the inclusions. We observe that the novel inversion method using solely boundary displacements and force measurements performs well in recovering the heterogeneous material/tissue composition that consists of one and two stiff inclusions embedded in a softer background material. Furthermore, the target shear modulus value for the stiffer inclusion region is underestimated and the inclusion size is overestimated when incomplete boundary displacements on some part of the boundary are utilized. For displacements measured on the entire boundary, the shear modulus reconstruction improves significantly. Additionally, we observe that with increasing number of displacement data sets utilized in solving the inverse problem, the quality of the mapped shear moduli improves. We also analyze the sensitivity of the shear modulus maps on the noise level varied between 0.1% and 5% white Gaussian noise in the boundary displacements, force and corresponding displacement indentation. Finally, a sensitivity analysis of the recovered shear moduli to the depth, stiffness and the shape of the stiff inclusion is performed. We conclude that this approach has potential as a novel imaging modality and refer to it as Mechanics Based Tomography (MBT).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Erratum: Mei, Y., et al. Mechanics Based Tomography: A Preliminary Feasibility Study. Sensors 2017, 17, 1075

The authors wish to correct Figures 12 and 14 in their paper published in Sensors [1], doi:10.3390/s17051075, http://www.mdpi.com/1424-8220/17/5/1075[...].

متن کامل

Feasibility Study of Real-time and Automated Monitoring of Iranian Rivers using 50-kHz Fluvial Acoustic Tomography System

Acoustic Tomography (AT) technique is an innovative method for real-time river monitoring. In this study, not only the accuracy of flow velocity measurement using 50 kHz AT system which is appropriate for narrow rivers (most Iranian rivers) is evaluated, but also its performance is compared with 30 kHz one which is used in wide rivers. The comparison results showed that the velocity resolutions...

متن کامل

Feasibility Assessment of Optical Coherence Tomography-Guided Laser Labeling in Middle Cranial Fossa Approach

Introduction: Different approaches have been developed to find the position of the internal auditory canal (IAC)in middle cranial fossa approach. A feasibility study was performed to investigate the combination of cone beam computed tomography (CBCT), optical coherence tomography (OCT), and laser ablation to assist a surgeon in a middle cranial fossa approach by outlining the internal auditory ...

متن کامل

Comparison between Needle Biopsy under Guide of Conventional Computerized Tomography (CCT) and Fluoroscopic Computerized Tomography (FCT) in Abdominal, Mediastinal, Lung, Pelvic, Bone, and Liver Masses

Background and Objective: Computerized tomography and fluoroscopic computerized tomography are amongst the methods used for guiding needle biopsy processes; however, fluoroscopic computerized tomography demonstrates the images during the process of biopsy. This study aims to compare and contrast the success of biopsy under guide...

متن کامل

The feasibility of direct treatment planning via contrast-enhanced computed tomography: an evaluation of dose differences based on the dimensional dose distribution comparison method

Background: We used a MapCHECK software-based dimensional dose distribution comparison method capable of evaluating point-to-point geometrical dose differences in volume to determine whether doses obtained from an enhanced computed tomography (CT)-based treatment plan, which better defines the target regions and organs at risk, differs from doses obtained from plain CT and then evaluated the fe...

متن کامل

A Preliminary Study for a Biomechanical Model of the Respiratory System

Tumour motion is an essential source of error for treatment planning in radiation therapy. This motion is mostly due to patient respiration. To account for tumour motion, we propose a solution that is based on the biomechanical modelling of the respiratory system. To compute deformations and displacements, we use continuous mechanics laws solved with the finite element method. In this paper, we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2017