SU-E-I-83: Evaluation of Penalizing Functions in Compressed Sensing to Recover Undersampled Data in PET Imaging.
نویسندگان
چکیده
PURPOSE Previously we proposed the use of compressed sensing (CS) techniques to recover partially sampled data in PET imaging (Valiollahzadeh et al IEEE MIC 2012). Here we compare the effect of various penalizing functions on the accuracy of the recovered activity concentration (AC) in PET imagesMethods: The recovery of partially sampled data using CS techniques requires minimizing a cost function describing a sparse model while being subject to the constraint of a partially observed data set. In this work we define the cost function as the summation of two terms: a Poisson log likelihood function to model the noise, and a penalty term to represent the sparse model. Four sparse models were evaluated: a TV model which assumes the image has a sparse representation in the finite difference domain; a linear combination of a wavelet and TV (WT) model; a recursive dyadic partitions (RDP) model which which estimates the structure of an image; and a variant of RDP that utilizes a cyclespun translation invariant version known as RDPTI. These 4 algorithms were tested using an IEC phantom containing 6 spheres (10:1 ratio). The phantom was imaged on a D-RX PET/CT scanner twice; once with all detectors operational (baseline) and once with 4 detector blocks at each of 0, 90, 180 and 270° turned off to create a partially sampled (PS) image. The PS image was corrected using the 4 different algorithms and the resultant images were compared to baseline by evaluating the mean AC in the spheres and background. RESULTS The average percent error in AC for the spheres (background) for the TV, WT, RDP and RDPI algorithms were 12.6(5.3), 4.3(5.1), 8.9(7.6), and 10.7(13)% respectively. CONCLUSION WT gave the most accurate AC and the least spurious artifacts suggesting its superior performance over the other algorithms.
منابع مشابه
Accelerating Magnetic Resonance Imaging through Compressed Sensing Theory in the Direction space-k
Magnetic Resonance Imaging (MRI) is a noninvasive imaging method widely used in medical diagnosis. Data in MRI are obtained line-by-line within the K-space, where there are usually a great number of such lines. For this reason, magnetic resonance imaging is slow. MRI can be accelerated through several methods such as parallel imaging and compressed sensing, where a fraction of the K-space lines...
متن کاملAccelerated 4D flow imaging using randomly undersampled echo planer imaging with compressed-sensing reconstruction
Introduction 2D phase contrast (PC) CMR is currently the standard clinical imaging sequence for evaluation of blood flow [1]. Recently, 3D time-resolved PC CMR (4D-PC) has been used for quantification and visualization of blood flow in all three directions of a volume [2]. However, such acquisitions require long scan times (often 10-20 minutes), which reduces its clinical feasibility and leads ...
متن کاملBlind Compressed Sensing Enables 3d Dynamic Free Breathing Mr Imaging of Lung Volumes and Diaphragm Motion
Objectives: The objective of this study is to increase the spatial and temporal resolution of dynamic 3D MR imaging of lung volumes and diaphragm motion. To achieve this goal, we evaluate the utility of the proposed blind compressed sensing (BCS) algorithm to recover data from highly undersampled measurements. Materials and Methods: We evaluated the performance of the BCS scheme to recover dyna...
متن کاملMO-D-141-05: Dictionary Learning in Compressed Sensing Using Undersampled Data in PET Imaging.
PURPOSE Compressed sensing in PET imaging usually leverages the sparse representation of the acquired data in a predefined domain to help recover potential undersampling in the sinogram space. The majority of CS methods use analytical predefined sparsifying transforms such as wavelets, curvelets, and finite transforms. In this work, we evaluate the dictionary learning (DL) transform to reconstr...
متن کاملQuantitative Evaluation of Temporal Regularizers in Compressed Sensing Dynamic Contrast Enhanced MRI of the Breast
PURPOSE Dynamic contrast enhanced magnetic resonance imaging (DCE-MRI) is used in cancer imaging to probe tumor vascular properties. Compressed sensing (CS) theory makes it possible to recover MR images from randomly undersampled k-space data using nonlinear recovery schemes. The purpose of this paper is to quantitatively evaluate common temporal sparsity-promoting regularizers for CS DCE-MRI o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Medical physics
دوره 40 6Part6 شماره
صفحات -