Methods and devices for measuring arterial compliance in humans.
نویسندگان
چکیده
This review analyses methods and devices used worldwide to evaluate the arterial stiffness. Three main methodologies are based upon analysis of pulse transit time, of wave contour of the arterial pulse, and of direct measurement of arterial geometry and pressure, corresponding to regional, systemic and local determination of stiffness. They are used in clinical laboratory and/or in clinical departments. Particular attention is given to the reproducibility data in literature for each device. This article summarizes the discussion of the dedicated Task Force during the first Conference of Consensus on Arterial Stiffness held in June 2000 (Paris, France).
منابع مشابه
بررسی کمپلیانس پارانشیم کلیه در اوروپاتی انسدادی حاد کلیه با کمک داپلر وریدی کلیه
V Zarrabi [1] , MD R Saloti [2] , MD Received: 18 Feb, 2009 Accepted: 22 July, 2009 Abstract Background & Aims: Renal stone is a common disease in GU system. Differential diagnoses of this problem are appendicitis, ectopic pregnancy, torsion of ovarian cyst which are important to be differentiated from each other. Sonography is a procedure for diagnosis of stone but it cannot diagnose ...
متن کاملValidity of Spo2 in Measuring of Oxygenation Index
Background Pulse-oximetry (Spo2) widely uses as a help tools for therapeutic interventions in the pediatric intensive care units (PICU). The aim of this study was to evaluate the validity of Spo2 in measuring of oxygenation index (OI) in children. Materials and Methods In a descriptive analytical study, 100 patients who were admitted to PICU Tabriz Children's Hospital were studied. Oxygenation ...
متن کاملEvaluation of the Quality Control Program for Diagnostic Radiography and Fluoroscopy Devices in Syria during 2005-2013
Introduction: Extensive use of diagnostic radiology is the largest contributor to total population radiation doses. Thus, appropriate equipment and safe practice are necessary for good-quality images with optimal doses. This study aimed to perform quality control (QC) audit for radiography and fluoroscopy devices owned by private sector in Syria (2005-2013) to verify compliance of performance o...
متن کاملSodium depresses arterial baroreceptor reflex function in normotensive humans.
Sodium may contribute to the pathogenesis of hypertension by impairing arterial baroreceptor reflex function. The objectives of this study were to 1) determine whether a high sodium diet depresses arterial baroreceptor reflex function in normotensive humans, and 2) determine whether alterations in baroreceptor reflex function are related to changes in arterial compliance. Seventeen normotensive...
متن کاملمقایسه بکارگیری دو روش تمرینات تنفسی غیر فعال دق دستی و ارتعاش مکانیکی بر عملکرد قلبی و ریوی بیماران تحت تهویه مکانیکی در بخش مراقبتهای ویژه
Introduction & Objective: passive respiratory exercises are used to prevent from accumulation of secretions, lung collapse and the incidence of ventilator-associated pneumonia in ICUs. This study is aimed to compare the effects of manual percussion and mechanical vibrations on cardiopulmonary functions of mechanically ventilated patients. Materials &Methods: This randomized crossover clinical...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- American journal of hypertension
دوره 15 8 شماره
صفحات -
تاریخ انتشار 2002