Characterization and utilization of a Bonner sphere set based on gold activation foils.
نویسندگان
چکیده
Bonner sphere (BS) sets which use activation foils as the central thermal neutron sensor have advantages over active BS systems in certain environments, for example, pulsed fields, or fields with high photon components. In such environments, they may be the only type of neutron spectrometer which can be used. This paper describes work, using both measurements and calculations, to validate the response functions for a BS set based on gold activation foils. As an illustration of the use of such a system, a measurement is described of the contaminant neutron spectrum in the treatment room of a 21 MV hospital linear accelerator providing photon beams for radiotherapy.
منابع مشابه
Response matrix evaluations of a passive Bonner sphere system used for neutron spectrometry at pulsed, intense and complex mixed fields
In the present work, the general purpose radiation transport MCNPX code (version 2.5.0) was used to evaluate the neutron fluence response matrix of the passive Bonner sphere spectrometer recently developed in our laboratory. The calculations were performed for an extended neutron incidence energy range (from 10−9 MeV to 1 GeV). Afterward, a sensitivity analysis of the main parameters affecting ...
متن کاملComparative Cyanide and Thiourea Extraction of Gold Based on Characterization Studies (TECHNICAL NOTE)
This study involved preliminary laboratory test work to identify the relative leaching response to cyanidation and thiourea leaching of an oxidized low grade gold ore based on characterization studies. Huge reserves of gold deposits have been reported from different parts of Iran, especially at Neishaboor area with gold grade of approx 4 ppm. For the mineralogical composition, the nature of the...
متن کاملEffect of Mechanical Activation on the Kinetics of Ammoniacal Thiosulfate Leaching of a Refractory Oxide Gold Ore
The effect of mechanical activation on the kinetics of ammoniacal thiosulfate leaching of a refractory oxide gold ore containing 2.8 ppm Au was investigated. The gold extraction of 99.81% was achieved by 16 h leaching of a sample mechanically activated for 60 minutes. The gold extraction observed for a similar reference sample without mechanical activation was only 55%. Studies revealed that le...
متن کاملSome Studies in Activation Foils for Measuring Low-Level Induced Activity for the Neutron Radiation Protection
For the measurement of induced activity in the activation foils, various methods and instruments are used. When the activity is measured by using a beta counter it is very important to know the beta attenuation in the activation foils. The beta attenuation in the foil depends on the beta spectrum of the activation product, the material and the thickness of the material. The beta attenuation has...
متن کاملHydroxyl capped silver-gold alloy nanoparticles: characterization and their combination effect with different antibiotics against Staphylococcus aureus
Objective(s): Metal nanoparticles (NPs) offer a wide variety of potential applications in pharmaceutical sciences due to the unique advances in nanotechnology research. In this work, bimetal Ag-Au alloy NPs were prepared and their combinations with other antibiotics were tested against Staphylococcus aureus. Materials and Methods: Firstly, Ag-Au alloy NPs with Au/Ag molar ratio of 1:1 was f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiation protection dosimetry
دوره 126 1-4 شماره
صفحات -
تاریخ انتشار 2007