Deconvolution has been used to correct first-pass radionuclide angiocardiography for the time course of the delivery of radiopharmaceutical into the cardiopulmonary system. The extreme sensitivity of deconvolution to random errors in the data may account for some of the problems encountered in practice. We implemented several deconvolution algorithms that were suitable for use with the unimodal and multimodal superior vena caval and pulmonary curves found in left-to-right shunt quantification. The sensitivity of the algorithms to random errors was assessed using mathematical test problems degraded with pseudorandom noise. An algorithm that constrained the deconvolved pulmonary curve to be expressable as the non-negative sum of a set of lagged normal curves was found to have the smallest maximum error on the curves tested. Comparison with results from a previously published test problem indicated an error reduction of greater than 50% over previously used algorithms. Use of this algorithm may permit more accurate deconvolution of pulmonary time-activity curves and thereby improve shunt quantification.
منابع مشابه
Multisensor Distributed Fusion Wiener Deconvolution Estimator for Linear Stochastic Multichannel ARMA Signal
Multisensor distributed fusion Wiener deconvolution estimator is presented in this paper. It does not need to solve the Diophantine equation, and the steady-state Kalman filter gain of the augmented system. It can handle processing of nonstationary signal. White noise estimator and A strom predictor are used in the algorithm. Gevers-Wouters (G-W) algorithm is also used in this paper. In order t...
متن کاملA novel deconvolution approach for high accuracy LOS estimation in WCDMA environments
A prerequisite for reliable mobile positioning in WCDMA systems is the estimation with high accuracy of the LineOf-Sight (LOS) propagation delay between 3 or more Base Stations (BSs) and the mobile station (MS). LOS component may be followed by Non Line-Of-Sight components arriving within less than one chip interval. Correlation based methods are limited in accuracy by the width of the main lob...
متن کاملPSO-Optimized Blind Image Deconvolution for Improved Detectability in Poor Visual Conditions
Abstract: Image restoration is a critical step in many vision applications. Due to the poor quality of Passive Millimeter Wave (PMMW) images, especially in marine and underwater environment, developing strong algorithms for the restoration of these images is of primary importance. In addition, little information about image degradation process, which is referred to as Point Spread Function (PSF...
متن کاملA comprehensive benchmark between two filter-based multiple-point simulation algorithms
Computer graphics offer various gadgets to enhance the reconstruction of high-order statistics that are not correctly addressed by the two-point statistics approaches. Almost all the newly developed multiple-point geostatistics (MPS) algorithms, to some extent, adapt these techniques to increase the simulation accuracy and efficiency. In this work, a scrutiny comparison between our recently dev...
متن کاملMulti-Modulus Algorithms Using Hyperbolic and Givens Rotations for MIMO Deconvolution
This paper addresses the problem of blind multipleinput multiple-output deconvolution of a communication system. Two new iterative blind source separation (BSS) algorithms are presented, based on the minimization of multi-modulus criterion. Further, we show that the design of algorithm in the complex domain is quite complicated, so a special structure of real filtering matrix is suggested and m...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of nuclear medicine : official publication, Society of Nuclear Medicine
دوره 24 3 شماره
صفحات -
تاریخ انتشار 1983