Extended Luenberger Observer-Based Fault Detection for an Activated Sludge Process
نویسندگان
چکیده
In this paper, an observer-based fault detection and isolation (FDI) method for a biological wastewater treatment process (WWTP) is presented. The residual is generated utilizing an Extended Luenberger function observer. The FDI of a set of sensors faults is done by using a bank of Luenberger observers. The implementation of the proposed approach and the results obtained from its application to the WWTP demonstrate its simplicity and effectiveness.
منابع مشابه
An Unknown Input Observer for Fault Detection Based on Sliding Mode Observer in Electrical Steering Assist Systems
Steering assist system controls the force transfer behavior of the steering system and improves the steering probability of the vehicle. Moreover, it is an interface between the diver and vehicle. Fault detection in electrical assisted steering systems is a challenging problem due to frequently use of these systems. This paper addresses the fault detection and reconstruction in automotive elect...
متن کاملPrevalence of antibiotic resistant genes in selected activated sludge processes in Isfahan Province, Iran
Wastewater treatment plants are one of the main sources of dissemination of antibiotic resistance genes (ARGs) into the environment. The present study was conducted to determine the prevalence and removal of ARGs in different wastewater treatment processes. A total of 36 samples from raw and final effluent of different activated sludge processes were collected and analyzed. Molecular analysis w...
متن کاملRobust Fault Detection and Isolation for Uncertain Linear Retarded Systems
A robust fault detection and isolation scheme is proposed for uncertain continuous linear systems with discrete state delays for both additive and multiplicative faults. Model uncertainties, disturbances and noises are represented as unstructured unknown inputs. The proposed scheme consists of a Luenberger observer for fault detection and a group of adaptive observers, one for each class of fau...
متن کاملA Robust Adaptive Observer-Based Time Varying Fault Estimation
This paper presents a new observer design methodology for a time varying actuator fault estimation. A new linear matrix inequality (LMI) design algorithm is developed to tackle the limitations (e.g. equality constraint and robustness problems) of the well known so called fast adaptive fault estimation observer (FAFE). The FAFE is capable of estimating a wide range of time-varying actuator fault...
متن کاملModel Study and Fault Detection for the Railway System
The wheel-rail-sleepers system is simulated as a series of moving point loads on an Euler–Bernoulli beam resting on a visco-elastic half space. This paper concentrates on the railsleepers interaction system (railway system) and the fault detection. The main objective is to mathematically develop and implement a dynamic model of a railway system then the diagnosis of system defects using a Luenb...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2008