Precise co-registration of SPECT and MRI for small animal imaging using a common animal bed with external references: A feasibility study
نویسندگان
چکیده
Introduction: Nuclear medicine (NM) can provide unique information about the distribution of receptors or sentinel lymph nodes (SLNs), although it shows poor anatomical information; therefore, the superimposition of NM images on MR images would enhance the excellent features of MRI in spatial resolution and tissue contrast. A high magnetic field, however, makes it difficult to develop a combined scanner [1, 2], especially in combination with a single photon emission computed tomography (SPECT) scanner that requires metallic collimators. The software-based post-processing precise fusion of images obtained by separate scanners would therefore be practical. In this study, we conducted a feasibility test of a post-processing method of high resolution SPECT (up to 1mm in spatial resolution) and MRI (up to 117μm in-plane resolution) co-registration in animal experiments. Since it is vulnerable to voluntary and involuntary animal motion during SPECT and MRI scans as well as in the interval between these scans, an in-house built animal bed for both scans (a common animal bed) was constructed to immobilize animals during experiments. Materials and methods: All MR images were acquired with a 3 T whole body scanner (Signa HDx, GE, Milwaukee, WI) equipped with a dedicated receiver coil for small animal use. SPECT images were acquired with a small animal scanner equipped with 4 detectors each of which has 9 multi-pinhole collimators (MPCs) (NanoSPECT CT; Bioscan, Washington DC). A common animal bed was constructed with an acrylic tube which has 3 small containers filled with radioisotope fluid used as external references in image co-registration. SPECT and MRI data were acquired separately and both image data sets with DICOM format were merged using commercially available software (In Vivo Scope ver1.37, BioScan, Washington, D.C.). A pilot study was conducted using a tubular water phantom in which 2 syringes containing Tc and CuSO4 solution, respectively, were placed in parallel. Signal profiles with respect to the location of the transverse axis were compared among SPECT, T1and T2-weighted MRI (T2WI), and merged images to verify that the co-registration procedure worked appropriately. Four male ddY mice then underwent SPECT-MRI fusion experiments, in which I iomazenil (IMZ) SPECT (45-66MBq i.v., acquisition counts of 110-165 x10, 24 projections, 300 sec/projection, OSEM reconstruction algorithm) and fast-spin echo T2WI (TR/effTE = 4000/80 ms) of the brain were merged in 2 mice, and in the other 2 mice Tc phytate interstitial SPECT lymphography (0.05ml of 74MBq/mL Tc phytate administered to the right foot pad) and T2WI (4000/60 ms) were merged to detect SLNs of the lower extremities. Results and discussion: Signal profiles of two syringe phantoms could be precisely matched on SPECT-MRI fusion images. MRI and I IMZ SPECT of the mouse brain were successfully merged and areas of strong uptake of I IMZ were comparable to those of high intensity on T2WI, showing that I IMZ accumulated in the cerebral cortex (Fig. 1). 99m Tc phytate SPECT and MR images were also completely co-registered. As a result, SLNs of the lower extremities less than 2mm in diameter could be clearly demonstrated in the popliteal region on a merged image (Fig. 2). Errors in the co-registration procedure were within 0.6 mm. Our in-house-built common animal bed with external markers avoided spatial mismatch, leading to accurate MRI-SPECT fusion images even for small animals. The combination of a high static magnetic field of 3 T with a highly sensitive receiver coil and a MPC SPECT facilitated in vivo observation of small animal organs such as tiny SLNs. The post-processing merge technique of MR images and SPECT ones may be a practical approach. Conclusion: A post-processing fusion technique of SPECT and MRI is feasible for simultaneous evaluation of functional and anatomical aspects in vivo of small animal organs, providing unique information. References [1] Nalcloglu O, et al. Proc. ISMRM 2007; 15: 920 [2] Goto T, et al. Proc. ISMRM 2008; 16: 1174
منابع مشابه
Precise Co-registration of SPECT and MRI for Small Animal Imaging using a Common Animal Bed with External References:Visualization of Macrophage Distribution within Inflammatory Lymph Nodes
Introduction: Nuclear medicine (NM) can provide unique information about sentinel lymph nodes, although it shows poor anatomical information; therefore, the superimposition of NM images on MR images would enhance the excellent features of MRI in spatial resolution and tissue contrast. A high magnetic field, however, makes it difficult to develop a combined scanner, especially in combination wit...
متن کاملEvaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study
Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...
متن کاملQuantitative SPECT and planar 32P bremsstrahlung imaging for dosimetry purpose –An experimental phantom study
Background: In this study, Quantitative 32P bremsstrahlung planar and SPECT imaging and consequent dose assessment were carried out as a comprehensive phantom study to define an appropriate method for accurate Dosimetry in clinical practice. Materials and Methods: CT, planar and SPECT bremsstrahlung images of Jaszczak phantom containing a known activity of 32P were acquired. In addition, Phanto...
متن کاملEvaluating the Recovery Process of Renal Ischemia/Reperfusion Injury in Rats Using Small-Animal SPECT
Background: Renal injuries associated with ischemia/reperfusion are a prevalent clinical phenomenon that can cause the emergence of progressive kidney diseases, eventually leading to chronic kidney injuries. The present study was conducted to evaluate the results obtained from non-invasive imaging using small-animal SPECT and investigate the recovery process in an animal model of renal ischemia...
متن کاملImaging of Clot by 99mTc-HMPAO Labeled Platelet in Animal Model Induced Thrombosis
99mTc-HMPAO labeled platelet (LP) imaging may integrate thrombosis imaging into routine clinical procedures. In the current study, we assessed the feasibility of the use of 99mTc-HMPAO LP for imaging of small clots in an animal model. Thrombosis was induced by application of FeCl3 solution in the distal part of the inferior vena cava (IVC) of a 6100 g anesthetiz...