Quantification of oxygen metabolic rates in Human brain with dynamic 17 O MRI: Profile likelihood analysis.

نویسندگان

  • Dmitry Kurzhunov
  • Robert Borowiak
  • Helge Hass
  • Philipp Wagner
  • Axel Joachim Krafft
  • Jens Timmer
  • Michael Bock
چکیده

PURPOSE Parameter identifiability and confidence intervals were determined using a profile likelihood (PL) analysis method in a quantification model of the cerebral metabolic rate of oxygen consumption (CMRO2 ) with direct 17 O MRI. METHODS Three-dimensional dynamic 17 O MRI datasets of the human brain were acquired after inhalation of 17 O2 gas with the help of a rebreathing system, and CMRO2 was quantified with a pharmacokinetic model. To analyze the influence of the different model parameters on the identifiability of CMRO2 , PLs were calculated for different settings of the model parameters. In particular, the 17 O enrichment fraction of the inhaled 17 O2 gas, α, was investigated assuming a constant and a linearly varying model. Identifiability was analyzed for white and gray matter, and the dependency on different priors was studied. RESULTS Prior knowledge about only one α-related parameter was sufficient to resolve the CMRO2 nonidentifiability, and CMRO2 rates (0.72-0.99 µmol/gtissue /min in white matter, 1.02-1.78 µmol/gtissue /min in gray matter) are in a good agreement with the results of 15 O positron emission tomography studies. Nonconstant α values significantly improved model fitting. CONCLUSION The profile likelihood analysis shows that CMRO2 can be measured reliably in 17 O gas MRI experiment if the 17 O enrichment fraction is used as prior information for the model calculations. Magn Reson Med 78:1157-1167, 2017. © 2016 International Society for Magnetic Resonance in Medicine.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of blood-brain-barrier permeability dysregulation and inflammatory activity in MS lesions by dynamic-contrast enhanced MR imaging

Objective: Measurement of blood-brain permeability dysfunction in active and chronic MS lesions with T1-weighted dynamic contrast-enhanced MRI to show variation in inflammatory activity Background: blood-brain-barrier perfusion characterization impaired in MS as some studies have shown recently buta comparison between perfusion parameters in contrast-enhanced and non-enhanced lesions not have ...

متن کامل

Mapping of cerebral oxidative metabolism with MRI.

Using a T(1rho) MRI based indirect detection method, we demonstrate the detection of cerebral oxidative metabolism and its modulation by administration of the mitochondrial uncoupling agent 2,4-dinitrophenol (DNP) in a large animal model with minimum utilization of gas. The study was performed by inhalation in swine during imaging on clinical MRI scanners. Metabolic changes in swine were determ...

متن کامل

Effect of Bias in Contrast Agent Concentration Measurement on Estimated Pharmacokinetic Parameters in Brain Dynamic Contrast-Enhanced Magnetic Resonance Imaging Studies

Introduction: Pharmacokinetic (PK) modeling of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) is widely applied in tumor diagnosis and treatment evaluation. Precision analysis of the estimated PK parameters is essential when they are used as a measure for therapy evaluation or treatment planning. In this study, the accuracy of PK parameters in brain DCE...

متن کامل

Development of (17)O NMR approach for fast imaging of cerebral metabolic rate of oxygen in rat brain at high field.

A comprehensive technique was developed for using three-dimensional (17)O magnetic resonance spectroscopic imaging at 9.4T for rapidly imaging the cerebral metabolic rate of oxygen consumption (CMRO(2)) in the rat brain during a two-min inhalation of (17)O(2). The CMRO(2) value (2.19 +/- 0.14 micromol/g/min, n = 7) was determined in the rat anesthetized with alpha-chloralose by independent and ...

متن کامل

An Efficient Framework for Accurate Arterial Input Selection in DSC-MRI of Glioma Brain Tumors

Introduction: Automatic arterial input function (AIF) selection has an essential role in quantification of cerebral perfusion parameters. The purpose of this study is to develop an optimal automatic method for AIF determination in dynamic susceptibility contrast magnetic resonance imaging (DSC-MRI) of glioma brain tumors by using a new preprocessing method.Material and Methods: For this study, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Magnetic resonance in medicine

دوره 78 3  شماره 

صفحات  -

تاریخ انتشار 2017