Abstract: Trigonocephaly: Are We Able to Establish Objective Clinical Parameters Without the Need for CT-Based Analysis?

نویسندگان

  • Jennifer L. McGrath
  • Lindsay Janes
  • Sai K. Vangala
  • Arun K. Gosain
چکیده

The patient was seen regularly and noted to have improvement in frontal appearance with resolution of trigonocephaly at 20-months of age. The frontal width improved to 95mm and intercanthal distance was 33mm. Repeat computed tomography scan showed a metopic ridge, but all prior characteristics of metopic synostosis were no longer present. The pre and post-orthotic therapy interfrontal angle were 94° and 98° (normal range 125–160°), respectively. Based on clinical findings, surgery was not recommended.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Abstract: Language Phoneme Discrimination in Infants with Sagittal Craniosynostosis: An ERP Study

M oday, Sptem er 6, 2016 CONCLUSIONS: Bitemporal to biparietal ratios are a quantitative, objective clinical measure that can be used to differentiate patients with significant trigonocephaly from those with metopic ridging but no significant cranial deformity. In no case of trigonocephaly did CT scan provide information that would alter surgical planning beyond that obtained from caliper measu...

متن کامل

Abstract: Standardized Protocol for Visual Surgical Plan and Three Dimensional Surgical Template-Assisted Single-Stage Mandible Contour Surgery

M oday, Sptem er 6, 2016 CONCLUSIONS: Bitemporal to biparietal ratios are a quantitative, objective clinical measure that can be used to differentiate patients with significant trigonocephaly from those with metopic ridging but no significant cranial deformity. In no case of trigonocephaly did CT scan provide information that would alter surgical planning beyond that obtained from caliper measu...

متن کامل

Stereotactic Body Radiotherapy for Lung Lesions using Multiple Phase 3D-CT Based on the Analysis of Radiobiological Parameters

Introduction: Planning target volume (PTV) is generated from internal treatment volume (ITV) using four-dimensional computed tomography (4D-CT) for enhanced therapeutic gain in the stereotactic body radiotherapy for lung lesions (SBRT-Lung). This study aimed to propose a strategy to generate ITV on multiple-phase 3D-CT and enhance therapeutic gain in SBRT-Lung. <stron...

متن کامل

Recognition and prediction of leukemia with Artificial Neural

  Abstract   Background : Leukemia is one of the mostcommon cancers in children, comprising more than a third of all   childhood cancers. Newly affected patients in USA are estimated as 10100cases, and if these cases are diagnosed late or proper treatment is not applied, then it can be mortal. Because rapid and proper diagnosis of leukemia based on clinical or medicinal findings (without biopsy...

متن کامل

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2016