Single‐isocenter hybrid IMRT plans versus two‐isocenter conventional plans and impact of intrafraction motion for the treatment of breast cancer with supraclavicular lymph nodes involvement
نویسندگان
چکیده
The purpose of this study was to compare the single-isocenter, four-field hybrid IMRT with the two-isocenter techniques to treat the whole breast and supraclavicular fields and to investigate the intrafraction motions in both techniques in the superior direction. Fifteen breast cancer patients who underwent lumpectomy and adjuvant radiation to the whole breast and supraclavicular (SCV) fossa at our institution were selected for this study. Two planning techniques were compared for the treatment of the breast and SCV lymph nodes. The patients were divided into three subgroups according to the whole breast volume. For the two-isocenter technique, conventional wedged or field-within-a-field tangents (FIF) were used to match with the same anterior field for the SCV region. For the single-isocenter technique, four-field hybrid IMRT was used for the tangent fields matched with a half blocked anterior field for the SCV region. To simulate the intrafraction uncertainties in the longitudinal direction for both techniques, the treatment isocenters were shifted by 1 mm and 2 mm in the superior direction. The average breast clinical tumor volume (CTV) receiving 100% (V(100%)) of the prescription dose (50 Gy) was 99.3% ± 0.5% and 96.4% ± 1.2% for the for two-isocenter and single-isocenter plans (р < 0.05), respectively. The breast CTV receiving 95% of the prescription dose (V(95%)) was close to 100% in both techniques. The average breast CTV receiving 105% (V(105%)) of the prescription dose was 32.4% ± 19.3% and 23.8% ± 13.3% (р = 0.08). The percentage volume of the breast CTV receiving 110% of the dose was 0.4% ± 1.2% in the two-isocentric technique vs. 0.1% ± 0.2% in the single-isocentric technique. The average uniformity index was 0.91 ± 0.02 vs. 0.91 ± 0.01 in both techniques (p = 0.04), but had no clinical impact. The percentage volume of the contralateral breast receiving a dose of 1 Gy was less than 2.3% in small breast patients and insignificant for medium and large breast sizes. The percentage of the total lung volume receiving > 20 Gy (V(20Gy)) and the heart receiving > 30 Gy (V(30Gy)) were 13.6% vs. 14.3% (р = 0.03) and 1.25% vs. 1.2% (р = 0.62), respectively. Shifting the treatment isocenter by 1 mm and 2 mm superiorly showed that the average maximum dose to 1 cc of the breast volume was 55.5 ± 1.8 Gy and 58.6 ± 4.3 Gy in the two-isocentric technique vs. 56.4 ± 2.1 Gy and 59.1 ± 5.1 Gy in the single-isocentric technique (р = 0.46, 0.87), respectively. The single-isocenter technique using four-field hybrid IMRT approach resulted in comparable plan quality as the two-isocentric technique. The single-isocenter technique is more sensitive to intra-fraction motion in the superior direction compared to the two-isocentric technique. The advantages of the single-isocenter include elimination of isocentric errors due to couch and collimator rotations and reduction in treatment time. This study supports consideration of a single-isocenter four-field hybrid IMRT technique for patients undergoing breast and supraclavicular nodal irradiation.
منابع مشابه
Comparing different techniques of Post Axillary field in Breast Cancer Treatment
As we know breast cancer is the second death reason in Iran. One step of treatment process is radiotherapy, which needs careful consideration of contouring and therapeutic techniques Lung, thyroid, spinal cord, trachea and humerus are sensitive organs in breast cancer radiation therapy. The most clinical studies recommended two ways for delivering 95 percent of dose to supraclavicular and ...
متن کاملHalf Beam Block Technique in Breast Cancer and It’s Dosimetric Analysis using different Algorithms
Introduction: Single isocentre half-beam block (HBB) technique permits the avoidance of hot and cold spots. This technique is very useful in sparing the underlying ipsilateral lung and heart, if the left breast is treated. The major advantage of this technique is that it facilitates the complete sparing of both contralateral breast and lung. Regarding this, the present study aimed to analyse th...
متن کاملDosimetric comparison of treatment of left breast cancer using two different dose schedules Dosimetric comparison of treatment of left breast cancer using two different dose schedules
Background: To date, different kinds of treatment methods have been proposed for radiotherapy of cancer patients. Choosing the kind of treatment method affects the quality of the patient's treatment. This study aims to investigate the effect of the number of radiation treatment sessions on the dose received by the patient and the distribution of tumor dose and dose received by organs at risk in...
متن کاملOptimization of tangential fields arrangement in the breast cancer 3D conformal radiation therapy
Introduction: The incidence of breast cancer increases with the rate of 1-2% at the world. Radiation therapy is one of the available choices for breast cancer treatment. The single isocentre half-beam block technique is considered as a standard technique to avoid hot and cold spots within the PTV. The major advantage of half beam technique is that the both contralateral breast...
متن کاملPretreatment quality control of single isocenter half- beam treatment planning technique using an amorphous silicon electronic portal-imaging device (EPID)
Introduction: Electronic portal imaging devices (EPIDs) are fundamentally used for instantaneous verification of the patient set‐up, block shape, and leaf positions during radiation therapy. In radiotherapy, situations arise in which an inclined PTV must be treated mutually with adjacent nodal regions. This methodology is most widely used for matching tangential/lateral breas...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -