Comparison of look-locker and MOLLI sequences for T1 mapping in hypertrophic and ischemic cardiomyopathy

نویسندگان

  • Xiaopeng Zhou
  • Melanie Traughber
  • Prabhakar Rajiah
  • Deborah Kwon
  • Paul Schoenhagen
  • Scott D Flamm
  • Randolph Setser
چکیده

Methods 5 control patients (4M/1F, age 44±21 y) with normal left ventricular (LV) function and no history of heart disease, 5 patients with ICM (3M/2F, 63±2 y), and 16 patients with HCM (10M/6F, age 51±15y) were recruited into an IRB approved protocol. All subjects were imaged at 1.5T (Achieva XR, Philips). T1 mapping was performed using MOLLI and LL at 2 LV short axis levels (basaland midcavity) before and after contrast agent injection (Magnevist; 0.2 mmol/kg). Post gadopentetate dimeglumine (Magnevist; 0.2 mmol/kg) injection time was about 15 min for HCM and ICM patients and was shorter (about 5 min) for the controls due to organizational reasons. For each subject, TI measurements were made in 6 ROIs per level.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

T1 mapping using a saturation recovery single-shot acquisition at 3 Tesla MRI in differentiation of normal myocardium from hypertrophic cardiomyopathy

Background Background Diffuse myocardial fibrosis is characteristic feature of hypertrophic cardiomyopathy (HCM). T1 mapping may enable non-invasive evaluation of diffuse myocardial fibrosis in HCM. There have been many studies that T1 mapping using a modified Look-Locker inversion recovery (MOLLI) sequence. However, there have been few studies using a SASHA for T1 mapping at 3 Tesla MRI. The p...

متن کامل

Regional diffuse fibrosis and strain characteristics differ between children with hypertrophic and dilated cardiomyopathy

Methods Consecutive pediatric subjects with HCM (n=12) or DCM (n=8) undergoing routine clinical CMR were recruited. Native and post contrast T1 mapping was performed using Modified Look-Locker inversion recovery (MOLLI) sequences in all subjects. In 10 subjects, the maximum and mean circumferential strains were also examined using Displacement Encoding With Stimulated Echoes (DENSE). Data for b...

متن کامل

True T1 mapping with SMART1Map (saturation method using adaptive recovery times for cardiac T1 mapping): a comparison with MOLLI

Background SMART1Map is a new single-point technique for cardiac T1 mapping [1]. Unlike Look-Locker approaches, such as MOLLI, which yield an “apparent” T1 (T1*), SMART1Map directly measures true T1. Because T1* is a function of imaging parameters, it is always shorter than T1, and correction methods are required to obtain the true T1. This work compared the accuracy of SMART1Map with MOLLI in ...

متن کامل

T1 values in discrimination between health and disease using different T1 sequences: comparison between 3'3'5-MOLLI, 3'5-MOLLI, shMOLLI and SASHA

Background Myocardial T1 mapping is emerging as a promising means to non-invasively discriminate between normal and diseased myocardium. Original modified Look-Locker sequence (3’3’5-MOLLI) can induce a long breath-hold and is prone to cardiac and respiratory motion. Several shorter sequences (3’5MOLLI, shMOLLI and SASHA) have been proposed for acquisition of T1 values. We examined native and p...

متن کامل

Myocardial T1 measurement: comparison of modified Look-Locker inversion recovery (MOLLI) and TI scout in the Multi-ethnic Study of Atherosclerosis (MESA)

Different cardiac MR acquisition sequences have been used to obtain myocardial T1 values. Among which available techniques, MOdified Look-Locker Inversionrecovery (MOLLI) and inversion-recovery TrueFisp (TI scout) sequences are widely used in research and clinical settings. We compared myocardial T1 values derived from both MOLLI and TI scout techniques in the post gadolinium delayed enhancemen...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -