Can Weight-Adapted IV Contrast Media Protocols Reduce Iodine Dose and Still Produce a Diagnostic Contrast Enhancement Level in Abdomino-Pelvic CT Scans?
ثبت نشده
چکیده
منابع مشابه
Assessment of Contrast Media Volume Injected and Image Contrast in Abdominal Pelvic CT Scan and Related Factors in Referral Hospitals in Mazandaran, Iran
Background and purpose: Computed tomography scan (CT) is highly capable of diagnosing abdominal and pelvic lesions. Injection of contrast media at appropriate concentration and volume provides the least side effects and the highest image quality. This study aimed at investigating the volume of contrast medium injected and the level of image contrast compared to the standard model, in the imagi...
متن کاملInduction of DNA damage, apoptosis and micronuclei in peripheral blood lymphocytes following injection of contrast media in patients with abdominal CT scan
Background: Medical diagnostic procedures such as X-ray and computed Tomography (CT) scan account for considerable percent of patient's exposure to ionizing radiation. The exposure of cells to Ionization radiation results in induction of DNA damage and chromosomal aberrations. Contrast media (CM) are widely used in diagnostic radiology and CT scan. The aim of this study was to study adverse gen...
متن کاملThe Feasibility of Thyroid Treatment with 99mTc Radiopharmaceuticals and Stable Iodine as Contrast Agent Using MCNP Simulation Code
Introduction: Nowadays, radioisotopes have a lot of therapeutic and diagnostic applications in nuclear medicine. The technetium-99m radioisotope is widely used in the diagnostic field. The technetium-99m radioisotope is widely used in the diagnostic field. In this study, in order to increase the absorption dose in thyroid cancer cells, the radioactive drug technetium-99m which ...
متن کاملThe influence of x-ray contrast agents in computed tomography on the induction of dicentrics and gamma-H2AX foci in lymphocytes of human blood samples.
The aim of this study was to investigate and quantify two biomarkers for radiation exposure (dicentrics and gamma-H2AX foci) in human lymphocytes after CT scans in the presence of an iodinated contrast agent. Blood samples from a healthy donor were exposed to CT scans in the absence or presence of iotrolan 300 at iodine concentrations of 5 or 50 mg ml(-1) blood. The samples were exposed to 0.02...
متن کاملThe effect of contrast agent on delivered dose during diagnostic imaging of thoracic region
This study evaluated the impact of contrast material on the estimation of absorbed dose due to computed tomography pulmonary angiography (CTPA) using the ICRP reference phantoms. To address this issue, we modified the previously developed physiologically based pharmacokinetic (PBPK) model to be conformed to the ICRP reference phantoms. Regarding the standard contrast material injection protocol...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2015