Method for the simultaneous determination of total polyphenol and anthocyan indexes in red wines using a flow injection approach.
نویسندگان
چکیده
A simultaneous and fast method for the determination of total polyphenol index (t.p.i.) and total anthocyan index (t.a.i.) has been developed by a flow injection approach and a diode array spectrophotometer for monitoring at 280 and 520 nm, respectively. Linear ranges were obtained from 20 to 70 index units and from 20 to 500 mg l(-1) for the t.p.i. and t.a.i., respectively. The results provided by the proposed method agree with those obtained using the polyphenol index at 280 nm and the Ribereau-Gayon method for the determination of total anthocyans. The sample throughout was 25-30 samples per hour. Analytical features such as repeatability, reproducibility and detection and quantification limits as well as the results of a robustness study based on the Steiner-Younden procedure are also given.
منابع مشابه
Simultaneous determination of dopamine and uric acid using a glassy carbon paste electrode modified with copper- para red complex
A simple approach based on cyclic voltammetry (CV) was developed for the simultaneous determination of dopamine (DA) and uric acid (UA) in the presence of ascorbic acid (AA) using a modified glassy carbon paste electrode (GCPE). In the present study, analytical parameters were optimized and electrochemical performance of modified electrode was investigated. The calibration curves were obtained ...
متن کاملDetermination of the polyphenol contents in Macedonian grapes and wines by standardized spectrophotometric methods
Wines and grapes contain a large array of phenolic compounds belonging to non-flavonoids and flavonoids. This study evaluates the polyphenolic contents of six commercial red and white Macedonian wines and four grape varieties. Spectrophotometric methods were applied for the determination of the total phenolics, the total flavonoids, the total anthocyanins and the total catechins. The efficiency...
متن کاملFlow Injection Determination of Total Catechins and Procyanidins in White and Red Wines
An easily automatable flow-injection (FI) method for the determination of total catechins is reported. The method is based on the reaction of vanillin in acid medium to yield a coloured product with maximum absorption at 500 nm. After optimisation by the univariate and multivariate approaches as required, the linear range was established (between 10 and 90 mgL and 10 and 250 mgL for white and r...
متن کاملDetermination of polyphenols in wines by reaction with 4-aminoantipyrine and photometric flow-injection analysis.
A new flow-injection analytical procedure is proposed for the determination of the total amount of polyphenols in wines; the method is based on the formation of a colored complex between 4-aminoantipyrine and phenols, in the presence of an oxidizing reagent. The oxidizing agents hexacyanoferrate(III), peroxodisulfate, and tetroxoiodate(VII) were tested. Batch trials were first performed to sele...
متن کاملDetermination of Total Antioxidant Activity of Wines Using a Flow Injection Method with Chemiluminescence Detection
Total antioxidant capacity (TAC) of several samples of red and white wines was investigated by means of a new analysis method of flow injection with chemiluminescence detection ((FIA-CL). The applied method is based on a chemiluminescence reaction between luminol and hydroxyl radicals generated by the hydrogen peroxide in the presence of Co(II) ions complexed with ethylene diamine tetraacetic a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Talanta
دوره 56 1 شماره
صفحات -
تاریخ انتشار 2002