Meta-analysis of thyroidectomy with ultrasonic dissector versus conventional clamp and tie
نویسندگان
چکیده
BACKGROUND We conducted a systematic review to evaluate the role of Ultrasonic dissector (UAS) versus conventional clamp and tie in thyroidectomy. MATERIALS AND METHODS We searched for all published RCT in into electronic databases. To be included in the analysis, the studies had to compare thyroidectomy with UAS versus conventional vessel ligation and tight (conventional technique = CT). The following outcomes were used to compare the total thyroidectomy group with UAS versus CT group: operative duration, operative blood loss, overall drainage volume during the first 24 hours, transiet laryngeal nerve palsy, permanent laryngeal nerve palsy, transiet hypocalcaemia and permanent hypocalcaemia. RESULTS There are currently 7 RCT on this issue to compare thyroidectomy with UAS versus CT. From the analysis of these studies it was possible to confront 608 cases: 303 undergoing to thyroidectomy with UAS versus 305 that were treated with CT. Actually, it was shown a relevant advantage of cost-effectiveness in patients treated with UAS; there is a statistically significant reduction of the operative duration (weighted mean difference [WMD], -18.74 minutes; 95% confidence interval [CI], (-26.97 to -10.52 minutes) (P = 0.00001), intraoperative blood loss (WMD, -60.10 mL; 95% CI, -117.04 to 3.16 mL) (P = 0.04) and overall drainage volume (WMD, -35.30 mL; 95% CI, -49.24 to 21.36 mL) (P = 0.00001) in the patients underwent thyroidectomy with UAS. Although the analysis showed that the patients who were treated with USA presented more favourable results in incidence of post-operative complications (transient laryngeal nerve palsy: P = 0.11; permanent laryngeal nerve palsy: not estimable; transient hypocalcaemia: P = 0.24; permanent hypocalcaemia: P = 0.45), these data didn't present statistical relevance. CONCLUSION This meta-analysis shown a relevant advantage only in terms of cost-effectiveness in patients treated with UAS; it is subsequent to statistically significant reduction of operation duration, intraoperative blood loss and of overall drainage volume during the first 24 hours. Although the analysis showed that the patients who were treated with UAS presented more favourable results in incidence of post-operative complications (transiet laryngeal nerve palsy; transiet hypocalcaemia and permanent hypocalcaemia), these data didn't present statistical relevance.
منابع مشابه
Total thyroidectomy with ultrasonic dissector for cancer: multicentric experience
BACKGROUND We conducted an observational multicentric clinical study on a cohort of patients undergoing thyroidectomy for thyroid carcinoma. The aim of this study was to evaluate the benefits of the use of ultrasonic dissector (UAS) vs. the use of a conventional technique (vessel clamp and tie) in patients undergoing thyroid surgery for cancer. METHODS From June 2009 to May 2010 we evaluated ...
متن کاملA systematic review and meta-analysis of Harmonic Focus in thyroidectomy compared to conventional techniques
INTRODUCTION Several meta-analyses have been performed comparing the use of a variety of ultrasonic devices in thyroidectomy to conventional procedures. These studies have shown the superiority of ultrasonic devices for most outcomes studied including faster operative time and less blood loss, and equivalent or better safety for recurrent laryngeal nerve paresis and hypocalcemia. The current wo...
متن کاملThyroidectomy with ultrasonic dissector: a multicentric experience.
INTRODUCTION We have conducted a clinical controlled trial (CCT) on patients who had undergone thyroidectomy for goitre or thyroid carcinoma. The endpoint of this study was to evaluate the benefits of ultrasonic dissector vs conventional technique (vessel ligation and tight) in patients undergoing thyroid surgery. PATIENT AND METHODS Between January 2007 and December 2009 a CCT was conducted ...
متن کاملA meta-analysis comparing the outcomes of LigaSure Small Jaw versus clamp-and-tie technique or Harmonic Focus Scalpel in thyroidectomy
BACKGROUND LigaSure (LS) Small Jaw is a surgical hemostasis equipment that is newly introduced in thyroid surgery. The objective of this study is to assess the short-term efficacy and safety outcomes of LS Small Jaw compared with clamp-and-tie technique or Harmonic Focus Scalpel in thyroidectomy. METHODS A literature search was performed in the PubMed and Embase databases (until June 12, 2016...
متن کاملThe use of Ultrasonic Dissector in the Prevention of Risk in Thyroid Surgery
Aim: The execution of a correct hemostasis in thyroid surgery is extremely important both for the recognition of the delicate anatomical structures surrounding the thyroid, and to avoid damage of the same with haemostatic maneuvers incongruous. The ultrasonic dissector, developed in ’90s, allows for adequate hemostasis of caliber vessels of diameter up to 3mm, and at the same time has a minimum...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 8 شماره
صفحات -