Method of Choice of Low TEWI Refrigerant Blends

نویسندگان

  • Charbel Rahhal
  • Denis Clodic
  • Charbel RAHHAL
  • Denis CLODIC
چکیده

The TEWI analysis of residential heat pumps shows that it is sensitive to refrigerant emissions and mainly dependent on the seasonal coefficient of performance of the heating unit. Otherwise for countries where electricity is mainly produced by a combination of nuclear-power and hydro-power, the direct emissions become not negligible compared to the indirect emissions. Both direct and indirect emissions must then be considered. The selection of new refrigerant candidates will depend on climatic conditions, the refrigerant global warming potential, the refrigerant safety and many other criteria such as the COP, the volumetric capacity and system operating pressures and temperatures. This paper presents a new method for the selection of refrigerant blends based on a series of selection criteria. The flammability analysis is based on experimental data of flammability limits and theoretical heat of combustion calculations. The chemical reactions are also introduced. The RF-number introduced by Kondo as an index for flammability classification is used. This method is applied to retrofit applications of air-to-water heat pumps installed for moderate temperatures hydronic heating systems (55°C-45°C). Alternative blends are compared to R-407C. A first general evaluation shows a few number of refrigerant blends with flammable and non flammable refrigerants. A second more restricted evaluation shows some other blends with slightly flammable candidates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Next Generation Refrigerants: Standards and Climate Policy Implications of Engineering Constraints

There is no single perfect refrigerant for diverse air conditioning, refrigeration, and industrial applications. The predominant halocarbons (CFCs, HCFCs, and HFCs) combine excellent efficiency and safety with acceptable costs. However, they contribute to ozone depletion potential (ODP) and/or global warming potential (GWP). The Montreal Protocol has eliminated ODP by requiring replacement of C...

متن کامل

Assessment of Propane in North American Residential Air Conditioning

Three unitary split systems were evaluated for use with propane as the refrigerant. These three systems were then compared to systems using hydrochlorofluorocarbon (HCFC) R-22 and hydrofluorocarbon (HFC) R-410A for environmental effectiveness. The propane systems included one using safety measures, another using propane with flame suppressant, and one using a secondary heat transfer loop to iso...

متن کامل

Energy Analysis of Various Supermarket Refrigeration Systems

Modeling and analysis work was done on various supermarket refrigeration systems for their energy efficiency, TEWI (Total Equivalent Warming Impact), and annual operating cost. The systems which were modeled in detail include parallel racks, distributed, self-contained, glycol secondary loop, and CO2 secondary loop (medium temperature) and cascade (low temperature). Based on R404A modeling resu...

متن کامل

Semi Empirical Calculation of Intermolecular Potentials and Transport Properties of Some Binary and Ternary Industrial Refrigerant Mixtures

In this study the intermolecular potential energies of some environment-friendly industrial HFC refrigerants were obtained through the inversion method which is based on the corresponding states principle. These potentials were later employed in calculation of transport properties (viscosity, diffusion, thermal conductivity and thermal diffusion factor) of some binary and ternary refrigerant mi...

متن کامل

Modelling of an Integrated Supermarket Refrigeration and Heating System Using Natural Refrigerants

This paper describes the development of a computer simulation model of an integrated supermarket refrigeration and heating system using natural refrigerants (namely ammonia and hydrocarbons). Initial resultS of the model's performance are presented, showing the influence of some of the operating parameters on system thermal efficiency. This will be validated using data collected from monitoring...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014