The characterization of cytokines in the interface tissue obtained from failed cementless total hip arthroplasty with and without femoral osteolysis.
نویسندگان
چکیده
The histologic, biochemical, and immunohistologic characteristics of the interface membranes surrounding the femoral component of failed cementless total hip arthroplasty (THA) in patients with (Group I) and without (Group II) radiographic evidence of focal endosteal erosion (osteolysis) were studied. Group I membranes had more macrophages and small particles of polyethylene debris in the membrane, but both groups had similar amounts of metal particles. A greater activity level of interleukin-1 (IL-1), tumor necrosis factor (TNF), and interleukin-6 (IL-6) was seen in the culture supernatant of the membranes from Group I than in that of Group II. Group I membranes also had more cells (macrophages, fibroblasts, and endothelial cells) that stained positively with anti-IL-6 antibody. These results suggest that IL-6, IL-1, and TNF play a role in the focal femoral osteolysis observed in patients with failed cementless hip prostheses.
منابع مشابه
Cementless Hip Arthroplasty in Southern Iran, Midterm Outcome and Comparison of Two Designs
Background: Cementless hip prosthesis was designed to provide biologic fixation, without the use of cement. The second generation components have shown more reliable bone ingrowths and survival rates. We are reporting a midterm result of two designs of cementless prosthesis in a unique culture with different social habits and expectations.Methods: 52 primary cementless total hip arthroplasty in...
متن کاملCementless Total Hip Arthroplasty After an Iatrogenic Subtrochanteric Fracture due to Hardware Removal: A Case Report
Introduction: Total hip arthroplasty (THA) after proximal femoral fixation is a challenging procedure due to possible hardware-related complications. Case presentation: A 78-year-old female with hip osteoarthritis had a proximal femoral osteotomy fixed using a blade plate in the same femur 41 years ago. A two-step approach was planned. After a challenging...
متن کاملPrimary total hip arthroplasty without the use of bone cement: a 10-year follow-up of 157 hips.
BACKGROUND The cementless fixation technique in total hip arthroplasty (THA) was developed to solve clinical problems such as aseptic loosening and osteolysis which were thought to be associated with the use of bone cement. This retrospective study reports our mid-term results with cementless THA. METHODS A series of 173 consecutive, unselected cementless THA procedures using the Omnifit pros...
متن کاملMedium-term results of cementless hydroxyapatite-coated primary total hip arthroplasty: a clinical and radiological review.
PURPOSE To evaluate the clinical and radiological outcomes following cementless primary hydroxyapatite-coated total hip arthroplasty. METHODS A retrospective study of 69 patients (82 hips) who underwent uncemented hydroxyapatite-coated Anatomic Benoist Girard total hip replacement between October 1991 and October 1995 at our institution was conducted. Patient records were reviewed. All patien...
متن کاملBead debonding from a modern cementless total hip femoral component with concomitant taper corrosion
We report a case of bead shedding from a cylindrical extensively porous-coated cementless femoral component with concomitant taper corrosion at the modular head-neck junction of a metal-on-polyethylene total hip prosthesis. The patient presented with chronic thigh pain 4 years after primary total hip arthroplasty, and radiographs revealed significant osteolysis and metallic debris around the fe...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical orthopaedics and related research
دوره 300 شماره
صفحات -
تاریخ انتشار 1994