Radiographic results of an accelerometer-based, handheld surgical navigation system for the tibial resection in total knee arthroplasty.

نویسندگان

  • Denis Nam
  • Michael Cross
  • Prashant Deshmane
  • Seth Jerabek
  • Michael Kang
  • David J Mayman
چکیده

In total knee arthroplasty (TKA), intramedullary and extramedullary tibial alignment guides are not proven to be highly accurate in obtaining alignment perpendicular to the mechanical axis in the coronal plane. The objective of this study was to determine the accuracy of an accelerometer-based, handheld surgical navigation system in obtaining a postoperative tibial component alignment within 2° of the intraoperative goal in both the coronal and sagittal planes. A total of 151 TKAs were performed by 2 surgeons using a handheld surgical navigation system to perform the tibial resection. Postoperatively, standing anteroposterior hip-to-ankle radiographs and lateral knee-to-ankle radiographs were performed to determine the varus/valgus alignment and the posterior slope of the tibial components relative to the mechanical axis in both the coronal and sagittal planes. Findings showed that 95.3% of the tibial components were placed within 2° of the intraoperative goal in the coronal plane and 96.1% of the components were placed within 2° of the intraoperative goal in the sagittal plane. Overall, mean postoperative lower-extremity alignment was -0.3°±2.1°, with 97% of patients having an alignment within 3° of a neutral mechanical axis. The handheld surgical navigation system improves the accuracy of the tibial resection and subsequent tibial component alignment in TKA. It is able to combine the accuracy of computer-assisted surgery systems with the ease of use and familiarity of conventional, extramedullary alignment systems, and the ability to adjust both the coronal and sagittal alignments intraoperatively may prove clinically useful in TKA.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cadaveric Results of an Accelerometer Based Pinless Navigation System for Tibial Resection in Total Knee Arthroplasty

Arthroplasty +Nam, D; Dy, CJ; Cross, MB; Lee, JH; Kim, S; Mayman, DJ Hospital for Special Surgery, New York, New York Senior Author: [email protected] PURPOSE: Total knee arthroplasty (TKA) has proven to be tremendously successful in the management of knee arthritis, but concerns still exist regarding component positioning, as a recent meta-analysis demonstrated 31.8% of TKAs performed with conve...

متن کامل

Using Accelerometer-Based Portable Navigation to Perform Accurate Total Knee Arthroplasty Bone Resection in Asian Patients.

Implant alignment is an important factor affecting clinical results associated with total knee arthroplasty (TKA). No report exists showing the utility of an accelerometer-based portable navigation system among patients with marked femoral bowing. The aim of this study was to evaluate the accuracy of a portable navigation system for implant alignment in Asian patients with marked femoral bowing...

متن کامل

High Tibial Valgus Osteotomy and Functional Outcome

Background: This is a case series of 76 knees of 62 patients who underwent upper tibial valgus osteotomy for treatment of medial compartment osteoarthritis during a 20-year period and who were followed for a mean of 7.6 years. Methods: The patients were evaluated by validated outcome assessment systems of general health status short form (SF-36), the Western Ontario McMaster osteoarthritis inde...

متن کامل

Unicompartmental Knee Osteoarthritis (UKOA): Unicompartmental Knee Arthroplasty (UKA) or High Tibial Osteotomy (HTO)?

  Background: The aim of this review article is to analyze the results of high tibial osteotomy compared to unicompartmental knee arthroplasty in patients with unicompartmental knee osteoarthritis.   Methods: The search engine used was PubMed. The keywords were: "high tibial osteotomy versus unicompartmental knee arthroplasty". Twenty-one articles were found on 28 February 2015, but only eighte...

متن کامل

The Impact of Pinless Navigation in Conventionally Aligned Total Knee Arthroplasty

Background Restoration of the mechanical axis is a main objective in total knee replacement (TKR). Aim of this study was to analyse the verification tool of a pinless navigation system in conventional TKR (cTKR). Methods In a prospective study, 147 TKR were performed by conventional technique. Using the "pinless verification" mode of a smartphone based navigation system, the cutting block pos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Orthopedics

دوره 34 10  شماره 

صفحات  -

تاریخ انتشار 2011