Some Accurately Measured Infrared Wavelengths for Calibration of Grating Spectrometers

نویسندگان

  • Earle K. Plyler
  • Norman M. Gailar
  • Thomas A. Wiggins
چکیده

The measured values of the wavelengths of 60 lines in the 1.1to 2.3-micron spectral region are reported. The absorption lines of the bands of methane and water vapor were used in the calibration. The methods of measurement are discussed. Also discussed are the methods of superimposing the well-known emission lines of several sources on the absorption lines that were measured. The values obtained for some lines are compared with values reported by other workers.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Retrieval of Co from Sciamachy Onboard Envisat

SCIAMACHY onboard the environmental research satellite ENVISAT is a UV/visible/near-infrared grating spectrometer providing 3 near infrared channels covering wavelengths from 1-1.75μm, 1.94-2.04μm and 2.262.38μm with moderate spectral resolution (0.22-1.5nm) (Bovensmann et al. 1999). Among the absorbers in these regions are the greenhouse gases CO2, CH4, N2O and H2O as well as CO. A modified DO...

متن کامل

Multi-octave spectral imaging in the infrared – a newly emerging approach

A new approach is described for obtaining spectral imagery over a broad range of infrared wavelengths, with high efficiency, and with a single grating element and focal plane array. The approach represents a simplification and mass reduction over the traditional approach involving multiple focal plane arrays, dispersing elements, and optical beamsplitters. The new approach has significant advan...

متن کامل

Procedures for Wavelength Calibration and Spectral Response Correction of CCD Array Spectrometers

This work describes a procedure for acquiring a spectrum of an analyte over an extended range of wavelengths and validating the wavelength and intensity assignments. To acquire a spectrum over an extended range of wavelengths with a spectrometer with a charge coupled device (CCD) array detector, it is necessary to acquire many partial spectra, each at a different angular position of the grating...

متن کامل

Wavelengths of spectral lines in mercury pencil lamps.

The wavelengths of 19 spectral lines in the region 253-579 nm emitted by Hg pencil-type lamps were measured by Fourier-transform spectroscopy. Precise calibration of the spectra was obtained with wavelengths of (198)Hg as external standards. Our recommended values should be useful aswavelength-calibration standards for moderate-resolution spectrometers at an uncertainty level of 0.0001 nm.

متن کامل

The Grating Spectrometer and Atomic Spectra

In the previous experiment diffraction and interference were discussed and at the end a diffraction grating was introduced. In this lab most of the things learned in the last experiment will be applied to measure the wavelengths of the lines in the visible spectrum of some elements. You will use a diffraction grating mounted on a spectrometer to measure the interference maxima for various wavel...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2006