This paper presents systematical investigations, including electrochemical activity, MTT cell assay and in vivo test, on the biocompatibility of three metallic glasses. The electrochemical behaviors and the cell toxicity of two newly developed TiZr-based metallic glasses (MGs), Ti42Zr40Si15Ta3 and Ti40Zr40Si15Cu5, with lower or without unfavorable elements are systematically investigated. Results show that the MGs with low Cu content exhibit a low electrochemical response. Cytotoxicity tests for the MGs and the mediums after the potential state test are evaluated with in vitro MTT assays. The solid specimens and the mediums after the potential state test for the pure Ti, Ti42Zr40Si15Ta3 and Ti40Zr40Si15Cu5 exhibit no significant cytotoxicity in the MTT test, while the tested medium for Ti45Cu35Zr20 MG shows lower cell viability. The inductively coupled plasma-mass spectrometry (ICP-MS) results also indicate that the Cu-rich sample released a significant amount of ions which may be the major factor causing the low viability in the MTT test. The good healing condition and the low C-reactive protein (CRP) index for the implanted New Zealand rabbits in a one-month in vivo test also show the satisfactory short-term biocompatibility of the TiZr-based MGs. The electrochemical measurements, in vitro, and in vivo experiments confirm that the developed TiZr-based MGs with lower Cu content (≦5%) are promising for biomedical purposes.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

In vitro biocompatibility response of Ti–Zr–Si thin film metallic glasses

In this study, the bio-electrochemical response of the Ti–Zr–Si thin film metallic glasses (TFMGs) in simulated body fluid with different contents of titanium is measured via potentiostat. According to the results of bio-corrosion potential and current, as well as the polarization resistance, it is concluded that the Ti66Zr25Si9 TFMGs possess the highest bio-electrochemical resistance. With inc...

متن کامل

Biocompatibility evaluation of sputtered zirconium-based thin film metallic glass-coated steels

Thin film metallic glasses comprised of Zr48Cu36Al8Ag8 (at.%) of approximately 1.5 μm and 3 μm in thickness were prepared using magnetron sputtering onto medical grade 316L stainless steel. Their structural and mechanical properties, in vitro corrosion, and antimicrobial activity were analyzed. The amorphous thin film metallic glasses consisted of a single glassy phase, with an absence of any d...

متن کامل

Recent Progress in Ti-Based Metallic Glasses for Application as Biomaterials

Ti-based bulk metallic glasses are of great interest in biomedical applications due to their high corrosion resistance, excellent mechanical properties and good biocompatibility. This article reviews recent progress in the development of Ti-based metallic glasses for the application as biomaterials. Ti-based (Ti­Zr­Cu­Pd, Ti­Zr­Cu­Pd­Sn, and Ti­Zr­Cu­Pd­Nb) bulk metallic glasses without toxic a...

متن کامل

In-vivo investigations and cytotoxicity tests on Ti/Zr-based metallic glasses with various Cu contents.

The Ti/Zr-based metallic glasses (MGs) with various Cu contents are prepared, with nominal compositions of Ti45Zr40Si15 (Cu-free), Ti45Zr40Si10Cu5 (low-Cu), and Ti45Zr20Cu35 (high-Cu). The mechanical properties, corrosion resistance, and in-vitro biocompatibility of these MGs are investigated by means of nano-indentation, electrochemical analyses, MTS assays and inductively coupled plasma mass ...

متن کامل

Screening Potential Biomaterials of Ti- and Zr-Based Metallic Glasses Rapidly

Corrosion phenomenon is the important factor in the field of biomaterial applications. The corrosion resistance of the metallic glasses was investigated by the cyclic voltammetry and a low-voltage potential state test of the cell membrane potential simulation in the simulation body fluid Hank’s solution in this paper. The potential Tiand Zr-based metallic glasses were screened rapidly to test t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Materials science & engineering. C, Materials for biological applications

دوره 43  شماره 

صفحات  -

تاریخ انتشار 2014