Effect of sodium dodecyl sulfate on protein separation by hollow fiber flow field-flow fractionation.
نویسندگان
چکیده
Effects of protein denaturation and formation of protein-sodium dodecyl sulfate (SDS) complexes on protein separation and identification were investigated using hollow fiber flow field-flow fractionation (HF5) and nanoflow liquid chromatography-electrospray ionization-tandem mass spectrometry (nLC-ESI-MS-MS). Denaturation and formation of protein-SDS complexes prior to HF5 separation resulted an increase in the retention of few protein standards due to unfolding of the protein structures and complexation, yielding ~30% increase in hydrodynamic diameter. In addition, low molecular weight proteins which could be lost from the HF membrane due to the pore size limitation showed an increase of peak recovery about 2-6 folds for cytochrome C and carbonic anhydrase. In the case of proteins composed of a number of subunits, denaturation resulted in a decrease in retention due to dissociation of protein subunits. A serum proteome sample, denatured with dithiothreitol and SDS, was fractionated by HF5, and the eluting protein fractions after tryptic digestion were analyzed for protein identification using nLC-ESI-MS-MS. The resulting pools of identified proteins were found to depend on whether the serum sample was treated with or without denaturation prior to the HF5 run due to differences in the aqueous solubility of the proteins. The enhancement of protein solubility by SDS also increased the number of identified membrane proteins (54 vs. 31).
منابع مشابه
Hollow fiber flow field-flow fractionation of proteins using a microbore channel.
Protein separation through hollow fiber flow field-flow fractionation (HF FlFFF) at microflow rate regime was successfully achieved by employing a microbore hollow fiber. In most of the flow field-flow fractionation (FlFFF) techniques applied to the separation of proteins, including hollow fiber FlFFF (HF FlFFF), an outflow rate leading to a detector has typically been a few tenths of a millili...
متن کاملEvaluation of multiplexed hollow fiber flow field-flow fractionation for semi-preparative purposes.
A multiplexed hollow fiber flow field-flow fractionation (MxHF5) is introduced to increase throughput of an HF5 channel system for semi-preparative purposes. HF5, a cylindrical version of the flow field-flow fractionation (FlFFF) operated with a porous, hollow fiber membrane by controlling the ratio of radial and axial flow rates, is capable of fractionating proteins, cells, and macromolecules ...
متن کاملDevelopment of non-gel-based two-dimensional separation of intact proteins by an on-line hyphenation of capillary isoelectric focusing and hollow fiber flow field-flow fractionation.
A rapid, non-gel-based, on-line, two-dimensional separation method is introduced for proteome analysis. Protein fractionation was carried out by first exploiting the differences in their respective isoelectric points (pI) in a Teflon capillary using isoelectric focusing (IEF), followed by a molecular weight (MW)-based separation in a hollow fiber by flow field-flow fractionation (FlFFF). The me...
متن کاملEffect of Temperature on Particle Separation in Hollow Fiber Flow Field-Flow Fractionation
Ž . Abstract: Hollow fiber flow field-flow fractionation HF-FlFFF has been tested Ž . by varying the temperature 21]738C to increase separation speed with reduced lift forces. It has been experimentally shown that the separation time of 0.050]0.426-mm polystyrene latex standards can be reduced approximately by half, at 598C, compared to the separation at room temperature. In addition, the resol...
متن کاملLanthanide phosphate nanorods as inorganic fluorescent labels in cell biology research.
density lipoproteins in normal humans. J Lipid Res 1982;23:97–104. 6. Scheffer PG, Bakker SJL, Heine RJ, Teerlink T. Measurement of LDL particle size in whole plasma and serum by high-performance gel-filtration chromatography using a fluorescent lipid probe. Clin Chem 1998;44:2148–51. 7. Teerlink T, Scheffer PG, Bakker SJL, Heine RJ. Combined data from LDL composition and size measurement are c...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 136 2 شماره
صفحات -
تاریخ انتشار 2011