High-performance liquid chromatographic method for determination of cefmetazole in human serum.

نویسندگان

  • M Sekine
  • K Sasahara
  • T Kojima
  • T Morioka
چکیده

A fast, specific, sensitive high-performance liquid chromatographic method for the determination of cefmetazole in human serum was developed. The serum samples were deproteinized by adding 5% trichloroacetic acid in methanol containing barbital as an internal standard and were injected onto a reverse-phase column (mu-Bondapak C18) with a mobile phase of 10 to 15% acetonitrile in 0.005 M citrate buffer (pH 5.4). Eluted components were detected by UV absorption at 254 nm. Cefmetazole and the internal standard were separated from interfering serum components by this method. The peak height ratio of cefmetazole to the internal standard was proportional to the cefmetazole concentration in the range from 0.4 to 100 micrograms/ml. Serum samples obtained from three patients after a single intravenous injection of cefmetazole were assayed by this method and by a microbiological method. There was a good correlation between two assay methods (correlation, coefficient, 0.98). The stability of cefmetazole in human serum was (correlation coefficient, 0.98). The stability of cefmetazole in human serum was also determined by this method. Cefmetazole was stable in human serum for 2 weeks at 4 degrees C or for at least 8 weeks if it was kept frozen. As the high-performance liquid chromatography method is simple, specific, accurate, and reproducible, it appears to be more suitable for routine assay of cephalosporins than other assay methods.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

HIGH-PERFORMANCE LIQUID CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE IN HUMAN SERUM

A simple, rapid and sensitive HPLC method for the determination of theophylline (T) in human serum has been developed. An isocratic system consisting of a /-l Bondapak C18 column, mobile phase of methanol, phosphate buffer (22:78, pH=4.5), and a flow rate of 1.4 mL/min was used. The eluent was detected by UV at 275 nm at room temperature. 8-Chlorotheophylline (8-CT) was used as an internal ...

متن کامل

High Performance Liquid Chromatographic Determination of Inactive Carboxylic Acid Metabolite of Clopidogrel in Human Serum: Application to a Bioequivalence Study

        A sensitive and rapid method is described for determination of clopidogrel carboxylic acid (CCA), the inactive metabolite of the antiplatelet agent clopidogrel in human serum. The analytical procedure involves liquid-liquid extraction of the analyte and an internal standard (phenytoin) with ethyl acetate. A mobile phase consisting of 0.05 M phosphate buffer containing triethylamine (0.5...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma

A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...

متن کامل

Rapid High Performance Liquid Chromatographic Determination of Risperidone in Human Plasma

A simple, rapid and sensitive high-performance liquid chromatographic (HPLC) method for the determination of risperidone in human plasma was developed. An HPLC system based on a Nucleosil C8 column (150?4 mm) and a UV detector (?= 280 nm) were used. A mixture of sodium dihydrogen phosphate buffer-acetonitrile (55:45, v/v) adjusted to pH 6.0 at a flow rate of 1.5 ml min-1 was used as mobile phas...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Antimicrobial agents and chemotherapy

دوره 21 5  شماره 

صفحات  -

تاریخ انتشار 1982