Devices for low flow O2 administration.

نویسندگان

  • A G Stewart
  • P Howard
چکیده

Long-term oxygen therapy requires a practical regulated oxygen delivery system which works in the home. Although face-masks are cheap and efficient, they are awkward and need removal for talking and eating. Few patients would comply with this for 15 h her day. Nasal prongs are reliable, cheap, safe and well tolerated but are wasteful of oxygen. This waste is important both practically and financially when oxygen is supplied from portable or large cylinders or from a liquid source. The Oxymizer pendants and moustache or inspiration phased delivery devices improve nasal prong efficiency. Nasopharyngeal catheters are an alternative but more invasive means of oxygen conservation. Percutaneous transtracheal catheterization is both oxygen efficient and cosmetically acceptable. As it requires an invasive surgical procedure with some serious potential complications its use should probably be reserved for those patients in whom adequate oxygenation is not achieved by standard nasal prongs. Its use is rarely justified on merely cosmetic grounds. Permanent tracheostomy is not indicated in most cases of hypoxic chronic obstructive airways disease (COAD). Nasal prongs would seem the most reasonable method of oxygen delivery. Their use with oxygen concentrators lessens the need for oxygen conservation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

AccuO2 oximetry-driven oxygen-conserving device versus fixed-dose oxygen devices in stable COPD patients.

BACKGROUND Because standard home oxygen (O2) systems deliver O2 at fixed rates, these systems are not designed to ensure optimal oxygen delivery based on physiologic need. We tested the ability of the AccuO2 (OptiSat Medical, Minneapolis, Minnesota), a portable, closed-loop, oximetry-driven, O2-conserving device to maintain SpO2 at ≥ 90%, compared to continuous-flow oxygen and a standard O2-con...

متن کامل

In-airway molecular flow sensing: A new technology for continuous, noninvasive monitoring of oxygen consumption in critical care

There are no satisfactory methods for monitoring oxygen consumption in critical care. To address this, we adapted laser absorption spectroscopy to provide measurements of O2, CO2, and water vapor within the airway every 10 ms. The analyzer is integrated within a novel respiratory flow meter that is an order of magnitude more precise than other flow meters. Such precision, coupled with the accur...

متن کامل

Fluidic Oscillators’ Applications, Structures and Mechanisms – A Review

Enhancement of heat and mass transfer and decrease of energy dissipation are great necessities of the evolution of fluid flow devices. Utilizing oscillatory or pulsatile fluid flow for periodic disturbing of velocity and thermal boundary layers is one of the methods with exciting results. Passive methods of generating oscillatory flow are preferred to active methods because of simplicity, no ne...

متن کامل

Oxygen Administration in the Emergency Department: Choosing the Appropriate Dosage and the Technology

Oxygen (O2), like any drug, should be administered only when indicated, and at the appropriate dose. The indications for O2 administration are to relieve global or regional hypoxia and to provide therapeutic hyperoxia. In treating hypoxia, one must first rule out low inspired O2 concentrations (FIO2). The causes of hypoxia can then be categorized into hypoventilation, which responds to small in...

متن کامل

Oral antioxidants improve leg blood flow during exercise in patients with chronic obstructive pulmonary disease.

The consequence of elevated oxidative stress on exercising skeletal muscle blood flow as well as the transport and utilization of O2 in patients with chronic obstructive pulmonary disease (COPD) is not well understood. The present study examined the impact of an oral antioxidant cocktail (AOC) on leg blood flow (LBF) and O2 consumption during dynamic exercise in 16 patients with COPD and 16 hea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 3 7  شماره 

صفحات  -

تاریخ انتشار 1990