Causes of failure in removing calcium in microcalcification-only lesions using 11-gauge stereotactic vacuum-assisted breast biopsy.

نویسندگان

  • Hatice Gümüş
  • Metehan Gümüş
  • Haresh Devalia
  • Philippa Mills
  • David Fish
  • Peter Jones
  • Aşur Uyar
  • Ali Sever
چکیده

PURPOSE The aim of this study was to determine the causes and rate of failure in removing calcification in microcalcification-only lesions using 11-gauge stereotactic vacuum-assisted breast biopsy. MATERIALS AND METHODS In total, 1365 microcalcification-only lesions were included in this study. The breast biopsy database was reviewed retrospectively. The biopsies were divided into two groups based on whether the specimen X-ray showed calcium within the cores. Breast composition, lesion size, calcification distribution, density on mammography, and the number of specimens were compared between the two groups. RESULTS In 11 (0.8%) biopsies, no calcium in the specimen radiography could be identified. Re-biopsy was performed in five cases. The initial biopsy result was unchanged at the second biopsy in three cases containing calcium, while in the other two cases, a benign biopsy result was upgraded to atypical ductal hyperplasia and ductal carcinoma in situ, respectively. In six cases, the biopsy was not repeated despite the absence of calcium in the specimen X-ray. In three of these cases, calcifications were reported histopathologically and deemed to be too small to be identified on specimen X-ray. In two of six patients, sufficient information was found in the cores without microcalcification to indicate the need for surgery. One patient refused re-biopsy. A statistically significant higher failure rate was observed in low-density calcification compared with intermediate or high-density calcification on mammography. CONCLUSION The failure to retrieve microcalcification is uncommon when an 11-gauge vacuum-assisted breast biopsy is used. Low-density calcifications have a higher rate of failure. In cases in which no calcium is observed in specimen radiography, repeated biopsy is recommended.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Breast microcalcifications: retrieval failure at prone stereotactic core and vacuum breast biopsy--frequency, causes, and outcome.

PURPOSE To retrospectively determine the frequency and causes of failure to retrieve microcalcifications in nonpalpable lesions, as judged on a radiograph of the specimen, and to determine outcome in patients with those lesions. MATERIALS AND METHODS Informed consent was obtained from each patient prior to biopsy. The institutional review board approved this HIPAA-compliant study and granted ...

متن کامل

A comparison of spring-loaded and vacuum-assisted techniques for stereotactic breast biopsy of impalpable microcalcification lesions: experience at Chang Gung Memorial Hospital at Linkou.

BACKGROUND The aim of this study was to assess the diagnostic performance of stereotactic core needle breast biopsy using spring-loaded or vacuum-assisted techniques for impalpable microcalcification lesions in Taiwanese women. METHODS We retrospectively reviewed the data of patients who received stereotactic core needle breast biopsy for impalpable mammographic microcalcification lesions fro...

متن کامل

Stereotactic vacuum-assisted breast biopsy: our experience and comparison with stereotactic automated needle biopsy.

OBJECTIVES To evaluate and compare the outcome of stereotactically guided percutaneous, directional, vacuum-assisted breast biopsy (VAB) with the outcome of those performed with 14-gauge automated gun. METHODS Between January 2008 and January 2011, altogether 257 stereotactic biopsies were performed in our institute; 193 with the 14-gauge automated needle and 64 with a directional, vacuum-ass...

متن کامل

Vacuum-assisted breast biopsy in close proximity to the skin: a case report

INTRODUCTION Vacuum-assisted breast biopsy is a minimally invasive technique used increasingly for the assessment of mammographically detected, non-palpable breast lesions. The effectiveness of vacuum-assisted breast biopsy has been demonstrated on lesions both with and without microcalcifications. Given that the position of the lesion represents a major factor in stereotactic vacuum-assisted b...

متن کامل

Vacuum-assisted stereotactic biopsy for isolated BI-RADS 4 microcalcifications: evaluation with histopathology and midterm follow-up results.

PURPOSE The aim of this study was to evaluate the 10-gauge vacuum-assisted stereotactic biopsy (VASB) of isolated Breast Imaging Reporting and Data System (BI-RADS) 4 microcalcifications, using histology and follow-up results. METHODS From January 2011 to June 2013, VASB was performed on 132 lesions, and 66 microcalcification-only lesions of BI-RADS 4 were included into our study. VASB was pe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Diagnostic and interventional radiology

دوره 18 4  شماره 

صفحات  -

تاریخ انتشار 2012