Measurement of six degrees of freedom head kinematics in impact conditions employing six accelerometers and three angular rate sensors (6aω configuration).

نویسندگان

  • Yun-Seok Kang
  • Kevin Moorhouse
  • John H Bolte
چکیده

The ability to measure six degrees of freedom (6 DOF) head kinematics in motor vehicle crash conditions is important for assessing head-neck loads as well as brain injuries. A method for obtaining accurate 6 DOF head kinematics in short duration impact conditions is proposed and validated in this study. The proposed methodology utilizes six accelerometers and three angular rate sensors (6aω configuration) such that an algebraic equation is used to determine angular acceleration with respect to the body-fixed coordinate system, and angular velocity is measured directly rather than numerically integrating the angular acceleration. Head impact tests to validate the method were conducted using the internal nine accelerometer head of the Hybrid III dummy and the proposed 6aω scheme in both low (2.3 m/s) and high (4.0 m/s) speed impact conditions. The 6aω method was compared with a nine accelerometer array sensor package (NAP) as well as a configuration of three accelerometers and three angular rate sensors (3aω), both of which have been commonly used to measure 6 DOF kinematics of the head for assessment of brain and neck injuries. The ability of each of the three methods (6aω, 3aω, and NAP) to accurately measure 6 DOF head kinematics was quantified by calculating the normalized root mean squared deviation (NRMSD), which provides an average percent error over time. Results from the head impact tests indicate that the proposed 6aω scheme is capable of producing angular accelerations and linear accelerations transformed to a remote location that are comparable to that determined from the NAP scheme in both low and high speed impact conditions. The 3aω scheme was found to be unable to provide accurate angular accelerations or linear accelerations transformed to a remote location in the high speed head impact condition due to the required numerical differentiation. Both the 6aω and 3aω schemes were capable of measuring accurate angular displacement while the NAP instrumentation was unable to produce accurate angular displacement due to double numerical integration. The proposed 6aω scheme appears to be capable of measuring accurate 6 DOF kinematics of the head in any severity of impact conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Kinematics and Dynamic Modelling of the Human Shoulder

This paper deals with kinematics and dynamics of the human shoulder in order to obtain the workspace related to the reachability of the wrist and applications to determine load for the wheelchair. The model contains six revolute degrees of freedom (D.O.F), two in costoclavicular and three in the shoulder joint and one in the elbow joint, while a six D.O.F model was developed according to given ...

متن کامل

A six degree of freedom head acceleration measurement device for use in football.

The high incidence rate of concussions in football provides a unique opportunity to collect biomechanical data to characterize mild traumatic brain injury. The goal of this study was to validate a six degree of freedom (6DOF) measurement device with 12 single-axis accelerometers that uses a novel algorithm to compute linear and angular head accelerations for each axis of the head. The 6DOF devi...

متن کامل

A feasibility study of dynamic verification for tumor target delineation and dose delivery using a six degrees of freedom motion phantom

Background: The dynamic phantom is one of the best tools to study the impact of motion on tumor target delineation and absorbed dose verification during dose delivery. Materials and Methods: this study, a 6-DOF (degrees of freedom) phantom was designed following the stacked serial kinematics and assembled by six commercial motion stages to generate 6-DOF motion, which were RotX (pitch, around X...

متن کامل

Kinematic and Gait Analysis Implementation of an Experimental Radially Symmetric Six-Legged Walking Robot

As a robot could be stable statically standing on three or more legs, a six legged walking robot can be highly flexible in movements and perform different missions without dealing with serious kinematic and dynamic problems. An experimental six legged walking robot with 18 degrees of freedom is studied and built in this paper. The kinematic and gait analysis formulations are demonstrated by an e...

متن کامل

Model Based Inertial Sensing for Measuring the Kinematics of Sit-to- Stand Motion

In this paper a method for measuring kinematics of sit-to-stand movement using inertial sensors and human body model is presented. The proposed approach fuses data from inertial sensors (accelerometers and gyroscopes) and data from three-segment human body model using Extended Kalman filtering technique and in this way reduces inaccuracies associated with inertial sensors. Dynamic human body mo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of biomechanical engineering

دوره 133 11  شماره 

صفحات  -

تاریخ انتشار 2011