Bi(III)4-methylpiperidinedithiocarbamate coprecipitation procedure for separation--pre-concentration of trace metal ions in water samples by flame atomic absorption spectrometric determination.

نویسندگان

  • Ayşegül Efendioğlu
  • Mehtap Yağan
  • Bekir Bati
چکیده

A pre-concentration method was developed for determination of trace amounts of cadmium, copper and lead in water samples by FAAS after coprecipitation by using potassium 4-methylpiperidinedithiocarbamate (K4-MPDC) as a chelating agent and Bi(III) as a carrier element. This procedure is based on filtration of the solution containing precipitate on a cellulose nitrate membrane filter following Cd(II), Cu(II) and Pb(II) coprecipitation with Bi(III)4-MPDC and then the precipitates together with membrane filter were dissolved in concentrated nitric acid. The metal contents of the final solution were determined by FAAS. Several parameters including pH of sample solution, amount of carrier element and reagent, standing time, sample volume for precipitation and the effects of diverse ions were examined. The accuracy of the method was tested with standard reference material (MBH, C31XB20 and CRM BCR-32) and Cd, Cu and Pb added samples. Determination of Cd, Cu and Pb was carried out in sea water, river water and tap water samples. The recoveries were >95%. The relative standard deviations of determination were less than 10%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Sepration and determination trace amount of cadmium ions in real and water samples by cloud point extraction - flame atomic absorption spectrophotometry after preconcentration with non-ionic surfactant Triton-X114

2-(3- indolyl) – 4,5 di phynyl imidazole.(IDPI) was used as a complexing agent in cloud point extraction for the first time and applied for selective pre-concentration of trace amounts of cadmium. The method is based on the extraction of cadmium at pH= 7.0 by using non-ionic surfactant Triton-X114 and 2-(3- indolyl) – 4,5 di phynyl imidazole. (IDPI) as a chelating agent. The adopted concentrati...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Review of preconcentration and solid phase extraction for the determination of trace Lead

Spectrometric techniques for the analysis of trace lead have developed rapidly due to the increasing need for accurate measurements at extremely low levels of this element in diverse matrices. This review covers separation and preconcentration procedures, and considers the features of the application with several spectrometric techniques. The use of an appropriate sample handling technique is a...

متن کامل

Extraction, preconcentration and spectrometric determination of Al (III) and Cr (III) ions using modified MnFe2O4 nanoparticles as an efficient adsorbent

An efficient and reusable adsorbent, namely 3-mercaptopropionic acid modified tetraethyl orthosilicate (TEOS) grafted MnFe2O4 nanoparticles (MPA-TEOS-MnFe2O4 NPs) was synthesized and used for the extraction and preconcentration of trace amount of Al (III) and Cr (III) ions in water samples. MnFe2O4 NPs were prepared by chemical c...

متن کامل

The determination of Cu2+, Fe3+, Zn2+ and Pb2+ in real samples by flame atomic absorption spectrometry after their separation- preconcentration on 2-(2-nitrophenylazo)- naphthalen-1-ol loaded on activated carbon

A sensitive and simple method for simultaneous preconcentration of trace heavy metal ions in some cerealand vegetable samples has been reported. The method is based on the adsorption of Cu2+, Fe3+, Zn2+ and Pb2+on 2-(2-nitro-phenylazo)-naphthalen-1-ol (NPN) loaded on activated carbon (AC). The adsorbed metals onactivated carbon were eluted using 3 ml 4 mol L−1 nitric acid. The influences of the...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of hazardous materials

دوره 149 1  شماره 

صفحات  -

تاریخ انتشار 2007