Usefulness of automatic detection of fragmented red cells using a hematology analyzer for diagnosis of thrombotic microangiopathy.

نویسندگان

  • K Saigo
  • M Jiang
  • C Tanaka
  • K Fujimoto
  • A Kobayashi
  • K Nozu
  • K Iijima
  • R Ryo
  • T Sugimoto
  • S Imoto
  • S Kumagai
چکیده

We previously reported an automatic method for quantitative analysis of schistocytes or fragmented red cells using an automatic hematology analyzer, XE-2100. In the study reported here, we evaluated the accuracy of this detection method in patients with thrombotic microangiopathy (TMA). A follow-up study was performed on 14 patients with two types of TMA, thrombotic thrombocytopenic purpura or hemolytic uremic syndrome. Schistocyte percent was evaluated both with an automatic counter and by means of microscopic observation. Total activity and isoenzyme pattern of lactate dehydrogenase (LD) were also determined. In these patients, schistocyte percent determined by automatic counting correlated highly with that determined by manual counting under microscopic observation (r = 0.852, P < 0.0001). Schistocyte percent was shown to correlate significantly with isoenzyme fractions 1 and 2 of LD (r = 0.732, P < 0.02), reflecting hemolysis. Nine of 11 patients tested had high concentrations of LD isoenzyme five without distinct liver damage, and schistocyte percent did not relate to fraction 5 of LD. Automatic detection of schistocyte percent using a hematology analyzer was useful for an accurate diagnosis and follow-up of thrombotic microangiopathy. The origin of LD fraction 5 remains to be determined.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Usefulness of sequential automated analysis of fragmented red blood cells for the differential diagnosis of thrombotic thrombocytopenic purpura-hemolytic uremic syndrome following allogeneic hematopoietic cell transplantation.

Differentiating thrombotic thrombocytopenic purpura-hemolytic uremic syndrome (TTP-HUS) from other complications following allogeneic hematopoietic cell transplantation (HPCT) requires objective, reliable markers. To this purpose, we assessed the clinical usefulness of sequential quantified analysis of fragmented red blood cells (FRC) with the Sysmex XE-2100 automated hematology analyzer. The c...

متن کامل

Quantification of red blood cell fragmentation by the automated hematology analyzer XE-2100 in patients with living donor liver transplantation.

The fragmented red cell (FRC) is a useful index for diagnosing and determining the severity of thrombotic thrombocytopenic purpura (TTP), thrombotic microangiopathy (TMA) and other similar conditions, as it is found in peripheral blood in patients with these diseases. The FRC expression rate has conventionally been determined by manual methods using smear samples. However, it is difficult to at...

متن کامل

The Clinical Significance of Schistocytes: A Prospective Evaluation of the International Council for Standardization in Hematology Schistocyte Guidelines

OBJECTIVE The presence of ≥1% schistocytes on a peripheral blood smear (PBS) is an important criterion for the diagnosis of thrombotic microangiopathy (TMA). The reporting of schistocytes has been standardized by the International Council for Standardization in Hematology (ICSH). Despite the availability of guidelines, however, the assessment of schistocytes remains subjective. More recently, t...

متن کامل

Effects of pre-analytical handling on selected canine hematological parameters evaluated by automatic analyzer

To assess the effects of pre-analytical handling (storage time and temperature) on selected hematological parameters, whole blood samples were collected in EDTA coated tubes from each of 30 clinically normal male adult beagle dogs. Each sample was separated in 2 aliquots, of which one was stored in ambient temperature (25 ˚C) and the other one was refrigerated (2 to 4 ˚C). Complete blood counts...

متن کامل

تفسیر هیستوگرام‏های اریتروسیتی به‌دست‌آمده از دستگاه‏های خودکار هماتولوژی در بیماری‏های خونی معمول

Background: Presently, the graphical data of blood cells (histograms and cytograms or/ scattergrams) that they are usually available in all modern automated hematology analyzers are an integral a part of automated complete blood count (CBC). To find incorrect results from automated hematology analyzer and establish the samples that require additional analysis, Laboratory employees will use thos...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical and laboratory haematology

دوره 24 6  شماره 

صفحات  -

تاریخ انتشار 2002