An automated tool for detection of FLAIR-hyperintense white-matter lesions in Multiple Sclerosis

نویسندگان

  • Paul Schmidt
  • Christian Gaser
  • Milan Arsic
  • Dorothea Buck
  • Annette Förschler
  • Achim Berthele
  • Muna Hoshi
  • Rüdiger Ilg
  • Volker J. Schmid
  • Claus Zimmer
  • Bernhard Hemmer
  • Mark Mühlau
چکیده

In Multiple Sclerosis (MS), detection of T2-hyperintense white matter (WM) lesions on magnetic resonance imaging (MRI) has become a crucial criterion for diagnosis and predicting prognosis in early disease. Automated lesion detection is not only desirable with regard to time and cost effectiveness but also constitutes a prerequisite to minimize user bias. Here, we developed and evaluated an algorithm for automated lesion detection requiring a three-dimensional (3D) gradient echo (GRE) T1-weighted and a FLAIR image at 3 Tesla (T). Our tool determines the three tissue classes of gray matter (GM) and WM as well as cerebrospinal fluid (CSF) from the T1-weighted image, and, then, the FLAIR intensity distribution of each tissue class in order to detect outliers, which are interpreted as lesion beliefs. Next, a conservative lesion belief is expanded toward a liberal lesion belief. To this end, neighboring voxels are analyzed and assigned to lesions under certain conditions. This is done iteratively until no further voxels are assigned to lesions. Herein, the likelihood of belonging to WM or GM is weighed against the likelihood of belonging to lesions. We evaluated our algorithm in 53 MS patients with different lesion volumes, in 10 patients with posterior fossa lesions, and 18 control subjects that were all scanned at the same 3T scanner (Achieva, Philips, Netherlands). We found good agreement with lesions determined by manual tracing (R2 values of over 0.93 independent of FLAIR slice thickness up to 6mm). These results require validation with data from other protocols based on a conventional FLAIR sequence and a 3D GRE T1-weighted sequence. Yet, we believe that our tool allows fast and reliable segmentation of FLAIR-hyperintense lesions, which might simplify the quantification of lesions in basic research and even clinical trials.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Automated White Matter Hyperintensity Detection in Multiple Sclerosis Using 3D T2 FLAIR

White matter hyperintensities (WMH) seen on T2WI are a hallmark of multiple sclerosis (MS) as it indicates inflammation associated with the disease. Automatic detection of the WMH can be valuable in diagnosing and monitoring of treatment effectiveness. T2 fluid attenuated inversion recovery (FLAIR) MR images provided good contrast between the lesions and other tissue; however the signal intensi...

متن کامل

Multiple Sclerosis lesion segmentation using Active Contours model and adaptive outlier detection method

The segmentation of Multiple Sclerosis (MS) lesions on Magnetic Resonance Imaging (MRI) has become a crucial criterion for diagnosis and predicting prognosis in early disease. Automated MS lesion segmentation is highly desirable for its low time computation, cost, effectiveness and minimum user bias. We proposed to develop and evaluate an automated lesion segmentation method based on Active Con...

متن کامل

"Central vessel sign" on 3T FLAIR* MRI for the differentiation of multiple sclerosis from migraine.

OBJECTIVE The diagnosis of multiple sclerosis (MS) presently relies on radiographic assessments of imperfect specificity. Recent data using T2* methodology for the detection of the "central vessel sign" (CVS) in MS lesions suggests this novel MRI technique may distinguish MS from other disorders. Our aim was to determine if evaluation for CVS on 3T FLAIR* MRI differentiates MS from migraine. ...

متن کامل

Evaluation the FLAIR Sensitivity and DWI Post-inject in Comparison with Delayed Enhancement T1w for Better Detection of Active MS Lesions

Background: Multiple sclerosis (MS) is a chronic, typically progressive and most common autoimmune disease which damaged the central nervous system. According to the reports in 2008, this disorder has affected 2 and 2.5 million people globally. While the reason is not clear, proposed causes for this include immunologic, environmental, infectious and genetic factors, and sexuality. MS can cause ...

متن کامل

Automated White Matter Lesion Segmentation in MRI using Box-Whisker Plot Outlier Detection

We report a new automated method for White Matter Lesions (WMLs) Segmentation in cranial MR Imaging. WMLs are diffuse white matter abnormalities which are often presented as hyperintense regions. In our approach, the presence of these abnormalities are detected as outliers in the intensity distribution of the FLAIR sequence using the histogram tails analysis and Box-Whisker plot technique. In a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • NeuroImage

دوره 59 4  شماره 

صفحات  -

تاریخ انتشار 2012