Elimination of toxicity from polyvinyl trays after sterilization with ethylene oxide.
نویسندگان
چکیده
Ethylene oxide (ETO) sterilization of polyvinyl trays used in an antiviral screening program was initiated to overcome seasonal outbreaks of bacterial and mycotic contamination of tissue culture cells. Trays sterilized by 100% ETO for 5 hr after 48 hr of prehumidification, or by 12% ETO plus 88% Freon 12 for 1, 3, 5 or 18 hr, followed by various methods of aeration, were seeded with several types of tissue culture cells and examined for contamination, toxicity, and monolayer quality. A 1-hr exposure in 12% ETO plus 88% Freon 12 was adequate for sterilization, although residual toxicity for tissue cultures remained. A 7-day aeration period at 37 C was sufficient to eliminate toxicity and allow the growth of good monolayers of WI-38, HEp-2 and primary bovine kidney cells. Sterilization with 100% ETO required 14 days of aeration at 37 C to eliminate cytotoxicity. Increased residual toxicity resulting from longer ETO sterilization periods required longer aeration times at 37 C or higher aeration temperatures for detoxification.
منابع مشابه
Sorption processes in gas sterilization in the medical sector.
Sorption of ethylene oxide during and after gaseous sterilization is influenced by numerous factors. It was found that ethylene oxide desorption not only depends on material to be fumigated but also to a considerable degree on the wrapping material. Although polyethylene, polyamide (nylon), polytetrafluoroethylene (Teflon), silicone, aluminum, and glass beads contained no quantities of ethylene...
متن کاملEthylene oxide resistance of nondesiccated and desiccated spores of Bacillus subtilis var. niger hermetically sealed in various polymeric films.
The resistance to destruction of spores of Bacillus subtilis var. niger hermetically sealed in various polymeric films and exposed to ethylene oxide with and without relative humidity was determined. The effect of desiccation was also determined. The order of increased resistance to sterilization with regard to type of polymeric film was found to be: polyethylene equal to polyvinyl chloride, le...
متن کامل[Compatibilities and incompatibilities between gamma rays and ethylene oxide as consecutive sterilization methods].
The doubt regarding the re-sterilization of articles made of polyvinyl chloride (PVC) sterilized with gamma radiation (GR) and subsequently with ethylene oxide (EO) persists to date. Through a systematic literature review, this article analyzed studies that demonstrated compatibilities and incompatibilities between the sterilization processes with GR and EO, when used as consecutive sterilizati...
متن کاملThe Sterilization of Bacteriological Media and Other Fluids with Ethylene Oxide
Ethylene oxide is an effective sterilizing agent for bacteriological broths, milk, and serum. A short time after it has exerted its sterilizing effect, the treated fluids again become capable of supporting bacterial growth. Ethylene oxide has been shown to destroy a number of aerobic Gram-positive and Gram-negative organisms, aerobic and anaerobic spore-forming bacilli, fungi, and vaccinia viru...
متن کاملSterilization by ethylene oxide.
Although sterilization by steam under pressure and by hot air are procedures which are now well understood and efficient when properly conducted, there is an increasing number of objects in medical or surgical use which are too heat labile to be so treated. It is for such items as plastic catheters, disposable plastic syringes, and prostheses that ethylene oxide has been proposed as a convenien...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied microbiology
دوره 18 6 شماره
صفحات -
تاریخ انتشار 1969