Measurement of the Q value of an acoustic resonator.

نویسندگان

  • Tetsushi Biwa
  • Yuki Ueda
  • Hiroshi Nomura
  • Uichiro Mizutani
  • Taichi Yazaki
چکیده

A cylindrical acoustic resonator was externally driven at the first resonance frequency by a compression driver. The acoustic energy stored in the resonator and the power dissipated per unit time were evaluated through the simultaneous measurements of acoustic pressure and velocity, in order to determine the Q value of the resonator. The resulting Q value, being employed as a measure of the damping in a resonator, was obtained as 36. However, the Q value determined from a frequency response curve known as a conventional technique turned out to be 25, which is 30% less than that obtained in the present method. By further applying these two methods in the case of a resonator having an acoustic load inside, we present an accurate measurement of the Q value of the resonator by making full use of its definition.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acousto-Refrigerator with an Adjustable Mechanical Resonator (RESEARCH NOTE)

Thermoacoustics describes energy conversion processes, activated by interaction temperature oscillation, accompanying the pressure oscillation in a sound wave, with solid boundaries. In ordinary experience this interaction of sound and heat cannot be observed, because of the very low temperature differences, but under suitable conditions, it can be emphasized and amplified to create remarkable ...

متن کامل

Evaluation of Acoustic Emission Inspection of Oil Tank Floor via Tank Bottom Plates Thickness Measurement

This paper deals with an inspection of defects including corrosion and leakage by Acoustic Emission (AE) in an oil tank floor. In contrast to intrusive methods such as magnetic flux leakage, eddy current or ultrasonic, there is no need to emptying and entering the tank in AE method in order to inspection. In this research AE investigation and AE source location is presented in detail. The resul...

متن کامل

Ultra-high Q Acoustic Resonance in Superfluid He

We report the measurement of the acoustic quality factor of a gram-scale, kilo-hertz frequency superfluid resonator, detected through the parametric coupling to a superconducting niobium microwave cavity. For temperature between 400mK and 50mK, we observe a T−4 temperature dependence of the quality factor, consistent with a 3-phonon dissipation mechanism. We observe Q factors up to 1.4 · 10, co...

متن کامل

High Q Power Divider/Combiner with High Output Isolation using Substrate Integrated Waveguide Technology

A power divider (PD)/ power combiner (PC) with high quality factor and enhanced output ports isolation using substrate integrated waveguide (SIW) technology is proposed. An SIW cavity is designed to provide a high quality factor filtering response and an SMD resistor is attached between two output ports to realize the high isolation. The value of the applied resistor is calculated by using the ...

متن کامل

Experimental Study of a Flash-lamp Pumped Passively Q-Switched Nd:YAG Laser Using Cr4+:YAG Saturable Absorber

This paper deals with the experimental results of a xenon flash-lamp pumped passively Q-switched Nd:YAG laser using Cr4+:YAG saturable absorber. The need of a laser cavity to be integrated into a time-of-flight laser range finder is of great interest as an experimental investigation of several laser resonators. Two types of laser resonator, with different lengths, have been studied: the flat-fl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physical review. E, Statistical, nonlinear, and soft matter physics

دوره 72 2 Pt 2  شماره 

صفحات  -

تاریخ انتشار 2005