Preliminary results of 3D dose calculations with MCNP-4B code from a SPECT image.

نویسندگان

  • M Rodríguez Gual
  • F F Lima
  • R Sospedra Alfonso
  • J González González
  • C Calderón Marín
چکیده

Interface software was developed to generate the input file to run Monte Carlo MCNP-4B code from medical image in Interfile format version 3.3. The software was tested using a spherical phantom of tomography slides with known cumulated activity distribution in Interfile format generated with IMAGAMMA medical image processing system. The 3D dose calculation obtained with Monte Carlo MCNP-4B code was compared with the voxel S factor method. The results show a relative error between both methods less than 1 %.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study

Background: Obtaining high quality images in Single Photon Emission Tomography (SPECT) device  is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in S...

متن کامل

Evaluation of Iridium_192 radioisotope dosimeter calculations for vascular Brachiotherapy

Introduction: One of the most effective means for treatment of coronary arteries cramp (CHD) is coronary intravascular Brachiotherapy. In this study, with use of MCNP code, in order to invastigating the score of ditribution of absorbed dose, drope in dose, and simulation mean, radiation doses around iridium_192 radioactive has been done.   Materials and Methods:</str...

متن کامل

-

Neutron dose-equivalent buildup factors were calculated for point isotropic neutron sources irradiating infinite slablike shields of lead, iron and water using the MCNP code. The factors are presented for some source neutron energies in the range from 0.025 eV to 14 MeV, and for shield thicknesses from 0.5 to 10 mfp. Since the MCNP code considers all kinds of neutron interactions with matter, a...

متن کامل

Investigation of Collimator Influential Parameter on SPECT Image Quality: a Monte Carlo Study

BACKGROUND Obtaining high quality images in Single Photon Emission Tomography (SPECT) device  is the most important goal in nuclear medicine. Because if image quality is low, the possibility of making a mistake in diagnosing and treating the patient will rise. Studying effective factors in spatial resolution of imaging systems is thus deemed to be vital. One of the most important factors in SPE...

متن کامل

Comparison of I-131, I-123 Absorbed Dose and Tc-99m in Thyroid Scanning Using MCNP Code in ORNL-MIRD Phantom

Introduction: Thyroid cancer is at the ninth from ten of common malignant cancer. A man has higher risk to get Thyroid cancer that a woman has. This organ is lain near human neck. The use of radioactive I-131, I-123 and Tc-99m for diagnosis of thyroid cancer has a risk where other organs around Thyroid will accept dose of radiation. One of the risks is large dose which is accep...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Revista espanola de medicina nuclear

دوره 23 6  شماره 

صفحات  -

تاریخ انتشار 2004