Validity and reliability of GPS for measuring instantaneous velocity during acceleration, deceleration, and constant motion.
نویسندگان
چکیده
In this study, we assessed the validity and reliability of 5 and 10 Hz global positioning systems (GPS) for measuring instantaneous velocity during acceleration, deceleration, and constant velocity while straight-line running. Three participants performed 80 running trials while wearing two GPS units each (5 Hz, V2.0 and 10 Hz, V4.0; MinimaxX, Catapult Innovations, Scoresby, VIC, Australia). The criterion measure used to assess GPS validity was instantaneous velocity recorded using a tripod-mounted laser. Validity was established using the standard error of the estimate (± 90% confidence limits). Reliability was determined using typical error (± 90% confidence limits, expressed as coefficient of variation) and Pearson's correlation. The 10 Hz GPS devices were two to three times more accurate than the 5 Hz devices when compared with a criterion value for instantaneous velocity during tasks completed at a range of velocities (coefficient of variation 3.1-11.3%). Similarly, the 10 Hz GPS units were up to six-fold more reliable for measuring instantaneous velocity than the 5 Hz units (coefficient of variation 1.9-6.0%). Newer GPS may provide an acceptable tool for the measurement of constant velocity, acceleration, and deceleration during straight-line running and have sufficient sensitivity for detecting changes in performance in team sport. However, researchers must account for the inherent match-to-match variation reported when using these devices.
منابع مشابه
The acceleration dependent validity and reliability of 10 Hz GPS.
OBJECTIVES To examine the validity and inter-unit reliability of 10 Hz GPS for measuring instantaneous velocity during maximal accelerations. DESIGN Experimental. METHODS Two 10 Hz GPS devices secured to a sliding platform mounted on a custom built monorail were towed whilst sprinting maximally over 10 m. Displacement of GPS devices was measured using a laser sampling at 2000 Hz, from which...
متن کاملNear-Minimum-Time Motion Planning of Manipulators along Specified Path
The large amount of computation necessary for obtaining time optimal solution for moving a manipulator on specified path has made it impossible to introduce an on line time optimal control algorithm. Most of this computational burden is due to calculation of switching points. In this paper a learning algorithm is proposed for finding the switching points. The method, which can be used for both ...
متن کاملThree-dimensional baselines for perceived self-motion during acceleration and deceleration in a centrifuge.
Three-dimensional motion trajectories were computed, representing the motions that would be perceived by a perfect processor of acceleration information during the acceleration and deceleration stages of a centrifuge run. These motions serve as "baselines" for perceived self-motion in a centrifuge, and depend on the initial perception of orientation and velocity immediately preceding the accele...
متن کاملDirect Optimal Motion Planning for Omni-directional Mobile Robots under Limitation on Velocity and Acceleration
This paper describes a low computational direct approach for optimal motion planning and obstacle avoidance of Omni-directional mobile robots within velocity and acceleration constraints on the robot motion. The main purpose of this problem is the minimization of a quadratic cost function while limitation on velocity and acceleration of robot is considered and collision with any obstacle in the...
متن کاملValidity and reliability of GPS and LPS for measuring distances covered and sprint mechanical properties in team sports
This study aimed to investigate the validity and reliability of global (GPS) and local (LPS) positioning systems for measuring distances covered and sprint mechanical properties in team sports. Here, we evaluated two recently released 18 Hz GPS and 20 Hz LPS technologies together with one established 10 Hz GPS technology. Six male athletes (age: 27±2 years; VO2max: 48.8±4.7 ml/min/kg) performed...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of sports sciences
دوره 30 2 شماره
صفحات -
تاریخ انتشار 2012