Residual blood in neonatal oxygenators after drainage.
نویسندگان
چکیده
The objective of this investigation was to measure the quantity of residual blood remaining in neonatal cardiopulmonary bypass (CPB) circuits after they had been drained and to assess the overall significance with regards to total patient blood volume. The residual blood volume left in three infant/neonatal CPB circuits-Medtronic Minimax 3381 (Group MM; n = 5), Polystan Safe Micro (Group SM; n = 6), and Terumo Capiox 308 (Group CX; n = 3)--after they had been drained was determined. This was done by using an electronic scale to weigh the circuit before setup and after CPB when all possible blood was recovered from it. Total priming volume, estimated patient blood volume, residual blood volume, surgical blood loss in theater, and autogeneic blood usage were recorded in each case. Mean residual blood volumes measured were MM = 161 ml (SD 27 ml), SM = 103 ml (SD 19 ml), and CX = 133 ml (SD 15 ml). These volumes were significant, because calculations show that the volume of red cells lost in the circuit is equivalent to fourteen percent of the total patient blood volume. In view of this, neonatal oxygenator design should be minimized to reduce the priming volume and more consideration should be given to ease of residual blood recovery.
منابع مشابه
Experimental use of an ultra-low prime neonatal cardiopulmonary bypass circuit utilizing vacuum-assisted venous drainage.
In adult cardiopulmonary bypass surgery, vacuum assisted venous drainage has become a popular technique to augment venous return to the bypass circuit. The application of this technique in neonatal cardiopulmonary bypass surgery could be beneficial to the further miniaturization of neonatal circuitry by coupling radical respositioning of the oxygenator and pump console with decreasing line leng...
متن کاملتاثیر دیربستن بند ناف بر پلی سایتمی نوزادی
Background and purpose : Âfter decades of discussion and debate, there is little agreement about appropriate time to clamp the umbilical cord after birth. With late cordclamping, neonate receives more placental transfusion that may affect blood hematocrit level. The purpose of this study was to evaluate the effect of early and late cordclamping on neonatal polycythemia at 2h and 18h after bir...
متن کاملFiltration of Cardiotomy
Microembolization resulting from platelet aggregation, air embolization and infusion of particulate material with stored and coronary suction blood has been implicated in the pathogenesis of certain complications following heart surgery'-s. In previous studies we have noted that particulate microembolization is reduced and platelet function is preserved following cardiopulmonary bypass with a m...
متن کاملNorth American neonatal extracorporeal membrane oxygenation (ECMO) devices and team roles: 2008 survey results of Extracorporeal Life Support Organization (ELSO) centers.
In early 2008, surveys of active extracorporeal membrane oxygenation (ECMO) centers in North America were conducted by electronic mail regarding neonatal ECMO equipment and professional staff. Eighty of 103 (78%) North American ECMO centers listed in the Extracorporeal Life Support Organization directory as neonatal centers responded to the survey. Of the responding centers, 82.5% routinely use...
متن کاملThoracoabdominal aneurysm rupture: a modification of the visceral perfusion circuit
A patient with ruptured type IV thoracoabdominal aortic aneurysm (TAAA), underwent surgical treatment utilizing visceral perfusion assisted by a centrifugal pump and neonatal membrane oxygenator. This circuit allows visceral perfusion with oxygenated blood during the ischemic period and the fast infusion of intravenous volume after clamp removal. Descriptors: Aortic aneurysm, thoracic, surgery....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The journal of extra-corporeal technology
دوره 30 4 شماره
صفحات -
تاریخ انتشار 1998