The objective of this study was to examine the repeatability of blood gas (BG) parameters and their derived variables such as the central venous-to-arterial carbon dioxide tension difference (▵PCO2) and the ratio of ▵PCO2 over the central arteriovenous oxygen content difference (▵PCO2/C(a-cv)O2) and to determine the smallest detectable changes in individual patients.A total of 192 patients with arterial and central venous catheters were included prospectively. Two subsequent arterial and central venous blood samples were collected immediately one after the other and analyzed using the same point-of-care BG analyzer. The samples were analyzed for arterial and venous BG parameters, ▵PCO2, and ▵PCO2/C(a-cv)O2 ratio. Repeatability was expressed as the smallest detectable difference (SDD) and the least significant change (LSC). A change in value of these parameters exceeding the SDD or the LSC should be regarded as real.The SDDs for arterial carbon dioxide tension, arterial oxygen saturation, central venous oxygen saturation (ScvO2), and ▵PCO2 were small: ±2.06 mm Hg, ±1.23%, 2.92%, and ±1.98 mm Hg, respectively, whereas the SDDs for arterial oxygen tension (PaO2) and ▵PCO2/C(a-cv)O2 were high: ±9.09 mm Hg and ±0.57 mm Hg/mL, respectively. The LSCs (%) for these variables were 5.06, 1.27, 4.44, 32.4, 9.51, and 38.5, respectively.The repeatability of all these variables was good except for PaO2 and ▵PCO2/C(a-cv)O2 ratio for which we observed an important inherent variability. Expressed as SDD, a ScvO2 change value of at least ±3% should be considered as true. The clinician must be aware that an apparent change in these variables in an individual patient might represent only an inherent variation.
منابع مشابه
Prognostic Value of Venous to Arterial Carbon Dioxide Difference during Early Resuscitation in Critically Ill Patients with Septic Shock
CONTEXT The partial pressure of venous to arterial carbon dioxide gradient (PCO2 gap) is considered as an alternative marker of tissue hypoperfusion and has been used to guide treatment for shock. AIMS The aim of this study was to investigate the prognostic value of venous-to-arterial carbon dioxide difference during early resuscitation of patients with septic shock and compared it with that ...
متن کاملCorrelation of Arterial Blood Gas Measurements with Venous Blood Gas Values in Mechanically Ventilated Patients
BACKGROUND Arterial blood gas (ABG) analysis is useful in evaluation of the clinical condition of critically ill patients; however, arterial puncture or insertion of an arterial catheter may cause many complications. The aim of this study was to determine whether venous blood gas (VBG) values can be used as an alternative to arterial blood gas measurements in patients under mechanical ventilati...
متن کاملCentral venous-to-arterial carbon dioxide difference as a prognostic tool in high-risk surgical patients
INTRODUCTION The purpose of this study was to evaluate the clinical relevance of high values of central venous-to-arterial carbon dioxide difference (PCO2 gap) in high-risk surgical patients admitted to a postoperative ICU. We hypothesized that PCO2 gap could serve as a useful tool to identify patients still requiring hemodynamic optimization at ICU admission. METHODS One hundred and fifteen ...
متن کاملAcid-base balance parameters and a value of anion gap of arterial and venous blood in Małopolski horses.
UNLABELLED The comparative study of the acid-base balance (ABB) parameters has been performed on 20 clinically healthy mature Małopolski horses. An arterial blood sample from the facial artery and a sample of venous blood from the external cervical vein were colected from each animal. In the samples tested, the blood pH, pCO2, tCO2, HCO3-, concentration of Na+, K+, Cl-, and a value of the anion...
متن کاملComparison of blood gas values in arterial and venous blood.
OBJECTIVE To compare pH and PCO2 values of simultaneously obtained arterial, arterialized capillary, and venous blood samples and also to compare oxygen saturation (ASaO2) measured in arterial blood and oxygen saturation by pulse oximetry (PSaO2). METHODS Prospective study was done in the children admitted in the Pediatric Intensive Care Unit of Christian Medical College Hospital Vellore, req...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 94 شماره
صفحات -
تاریخ انتشار 2015