Validation and initial application of a semiautomatic aneurysm measurement software: a tool for assessing volumetric packing attenuation.

نویسندگان

  • H Takao
  • T Ishibashi
  • T Saguchi
  • H Arakawa
  • M Ebara
  • K Irie
  • Y Murayama
چکیده

BACKGROUND AND PURPOSE Precise aneurysm measurements and volume embolization ratios are essential for long-term durability of endovascular coil embolization. We evaluated the accuracy of newly developed semiautomatic cerebral aneurysm measurement software, NeuroVision, and explored the value of volume embolization ratio in the prediction of re-treatment. MATERIALS AND METHODS We compared software-derived volume measurements of 4 silicone aneurysm models with those calculated with an approximation formula and ground truth values (validation study). We used NeuroVision to retrospectively evaluate outcomes of 100 unruptured aneurysms (97 patients) treated with embolization (clinical study). Aneurysm size (height, width, and neck), volume, and volume embolization ratios were calculated for 3 groups (stable, recanalization, and re-treatment) and were compared. RESULTS This validation study illustrated higher accuracy of NeuroVision in computing aneurysm volume compared with an approximation formula: percentage absolute errors were 4.50% ± 3.18% and 23.07% ± 17.60%, with maximal percentage absolute errors of 8.99% and 45.63%, respectively. Of 100 unruptured aneurysms, 20 recanalized and 12 were re-treated. Average volume embolization ratios of stable and re-treated aneurysms were 24.88% ± 5.91% and 20.50% ± 4.06%, respectively (P ≤ .01). The optimal volume embolization ratio cutoff point for re-treatment was < 19.15%, at which the Youden index was 0.50 (sensitivity, 58.33%; specificity, 87.50%; area under the receiver operating characteristic curve, 0.74). CONCLUSIONS The NeuroVision software provided accurate aneurysm volume measurements and may be a useful standardized tool to measure aneurysm size and volume, especially for multicenter clinical studies. Volume embolization ratio may be a valuable predictor of aneurysm occlusion changes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Volume Measurement of the Intracranial Aneurysm: A Discussion and Comparison of the Alternatives to Manual Segmentation

OBJECTIVE Several modalities are available for volumetric measurement of the intracranial aneurysm. We discuss the challenges involved in manual segmentation, and analyze the application of alternative methods using automatic segmentation and geometric formulae in measurement of aneurysm volumes and coil packing density. METHODS The volumes and morphology of 38 aneurysms treated with endovasc...

متن کامل

Assessing coaching moral competences: Development and initial validation of the Coaching Fairplay Behaviors Inventory

The purpose of the present investigation was to develop and initial validation of a measure for assessing the athletes perceptions of coaches’ behaviors that promote fairplay behaviors. A three-step procedure was undertaken to develop the questionnaire. In the initial step, the literature review provided theoretical and empirical perspectives on how youth sport coaches can influence athletes’ f...

متن کامل

Development and validation of a short form of the self-efficacy measurement tool for Iranian patients with myocardial infarction

To assess efficacy in patients with heart failure need to have a scientific tool based on psychometric features is evident. The researchers developed a scientific tool based on psychometric principles for assessing self-efficacy beliefs in patients with Myocardial Infarction (MI) as the only tool of its kind; however, Due to the large number of questions in the questionnaire, respondents may no...

متن کامل

Assessing Organizational Readiness for Change; Comment on “Development and Content Validation of a Transcultural Instrument to Assess Organizational Readiness for Knowledge Translation in Healthcare Organizations: The OR4KT”

This commentary provides an overview of the organizational readiness for change (ORC) literature over the last decade, with respect to prevailing definitions, theories, and tools to guide assessment of ORC in preparation for implementation. The development of the OR4KT by Gagnon et al is an important contribution to this body of work. This commentary highlights the strengths of the OR4KT includ...

متن کامل

Development and Validation of Sound Transmission Loss Measurement System for Measuring Muffler Performance

Muffler is a part of the vehicle exhaust system that absorb or reflect sound waves to reduce exhaust noise. One of the most important determinants of a muffler performance is the amount of attenuation that has on its input wave; this parameter is known as sound transmission loss. Four - mic standard test is one way to determine this parameter which is used in this paper. In this study, a test d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • AJNR. American journal of neuroradiology

دوره 35 4  شماره 

صفحات  -

تاریخ انتشار 2014